SPECIFICATIONS

Table 2. Thermostat specifications.

Power

 

Power Supply

24 Vac nominal, 18-30 Vac, 50/60 HZ.

Electrical Rating
      

Heating rating

      Cooling rating
      Fan rating

Note: 

The fan load plus the higher of the heating or

cooling load must not exceed 1.5 Amp continuous

0.02 to 1.5 A continuous
0.02 to 1.5 A continuous
0.02 to 0.5 A continuous

TEMPERATURE  RATINGS

      Temperature setting range
      Ambient temperature range

 

Shipping temperature range

40 to 99 

°

F  (4 to 37 

°

C)

40 to 110

 

°

F (4 to 43 

°

C)

14 to 140 

°

F (-10 to 60 

°

C)

OPERATING RELATIVE HUMIDITY

5 to 90% RH, non-condensing

CYCLE RATES

     Cooling mode
     Heating mode

3  Cycles Per Hour
1,3,4,5,6,9,12  Selectable Cycles Per Hour

DIMENSION

Fig. 2.Thermostat dimension

Содержание TE86S

Страница 1: ...hermostat Model Mounting System Selection Fan Selection Powering Method Backlight TE86S VERTICAL COOL OFF HEAT ON AUTO Power Stealing No Backlight TE86SB VERTICAL COOL OFF HEAT ON AUTO Power Stealing...

Страница 2: ...d 1 5 Amp continuous 0 02 to 1 5 A continuous 0 02 to 1 5 A continuous 0 02 to 0 5 A continuous TEMPERATURE RATINGS Temperature setting range Ambient temperature range Shipping temperature range 40 to...

Страница 3: ...as indicated will result in poor temperature control NOTE Level thermostat mounting is for appearance only and is not required for proper thermostat operation Mounting Thermostat Take out the back pl...

Страница 4: ...s used may result in the overheating of the electric heater elements due to improper fan operation The set up switch is an internal switch E F located near the wiring terminals It is used to select pr...

Страница 5: ...following steps to change each of the settings Each time you press D key you will advance to the next operating parameter To go back you must re enter the installer set up as described above INSTALLER...

Страница 6: ...hould consult with the heating equipment manufacturer for proper use Setting cooling algorithm OP 04 The cooling algorithm can be selected as normal or aggressive For aggressive the system will cool d...

Страница 7: ...and cooling are off Fan Setting Fan switch settings are On Fan symbol is indicated on the display The fan runs continuously Used to improve air circulation and air quality Auto Fan and Auto symbols a...

Страница 8: ...p switch is in the F position the fan is controlled directly by the heating equipment and may start a few minutes after the heating equipment turns on When setup switch is in the E position the fan st...

Отзывы: