background image

DIGITAL 

THERMOMETER 

WITH TRICOLOR LCD

INSTRUCTION MANUAL

THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, 
MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ CAREFULLY AND 
UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS. 
FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY AND/OR PROPERTY 
DAMAGE.
IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH YOUR ALLTRADE 
PRODUCT, DO NOT RETURN THIS PRODUCT TO THE STORE. PLEASE CALL OUR CUSTOMER 
SERVICE DEPARTMENT AT 

1-800-423-3598

. BEFORE YOU CALL, HAVE THE FOLLOWING 

INFORMATION AVAILABLE: MODEL No., DATE PURCHASED AND STORE LOCATION. AN 
ALLTRADE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE. IF YOU 
WOULD LIKE TO MAKE A SUGGESTION OR COMMENT, GIVE US A CALL OR EMAIL US AT: 
[email protected]. YOUR FEEDBACK IS VITAL TO US.

Model no 240022

Component No. 692650

Содержание 240022

Страница 1: ...ERTY DAMAGE IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH YOUR ALLTRADE PRODUCT DO NOT RETURN THIS PRODUCT TO THE STORE PLEASE CALL OUR CUSTOMER SERVICE DEPARTMENT AT 1 800 423 3598 BEFORE YOU CALL HAVE THE FOLLOWING INFORMATION AVAILABLE MODEL No DATE PURCHASED AND STORE LOCATION AN ALLTRADE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE IF YOU WOULD LIKE TO MAKE A SUGGEST...

Страница 2: ...ring the amount of infrared energy radiated from the object s surface GENERAL SAFETY RULES READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow all instructions in this manual may result in severe personal injury or death Keep this manual and refer to it for Safety Instructions Operating Procedures and Warranty SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE RECOGNIZE SAFETY SYMBOLS WORDS AND LABEL...

Страница 3: ...s or injuries resulting from not following these instructions will be refused Never operate laser if the unit is defective or the cover or seal is damaged There are no user serviceable parts in the laser device The laser unit must be returned to the factory for any service or repair Service or repair must be handled by authorized factory trained techni cians Be careful with this tool Striking or j...

Страница 4: ...rget The IR thermometer cannot measure through transparent surfaces such as glass and plastic It will measure the surface temperature instead Steam dust smoke and or vapours can prevent accurate measurement by obstructing the unit s optics For better accuracy keep the sensor perfectly clean Refer to the spot size information on the instrument and in the manual for the target spot size being measur...

Страница 5: ...ng accuracy when the low battery icon appears replace thermometer s battery 1 Place fingers behind the battery housing cover tabs and gently pull open the cover 2 Pull the plastic ribbon under the batteries to pull the batteries out 3 Insert two fresh AA Alkaline batteries with correct polarity as shown by the marking on the side of battery housing over the plastic ribbon inside the housing Close ...

Страница 6: ...nter to aim at the object more accurately 2 Release the trigger to display the Most Recent temperature reading The display will Remain and automatically will shut off after Approximately 1 minute 3 For accurate temperature measurement ALWAYS follow the D S 11 1 ratio rule For example if the diameter of the surface S is 1 ft the distance D between the IR thermometer and surface should be LESS than ...

Страница 7: ...D color will be in green If Reference Temperature mode is turned off the default LCD color is yellow 1 Aim the thermometer at the surface spot to be used as reference temperature and press the trigger 2 While pressing the trigger briefly press the SET button After appearance of the reference temperature value at the top right corner of the LCD display and a short beep the reference value is saved ...

Страница 8: ...ue press the SET button for a few seconds to save the value in the thermometer mem ory and exit the emissivity adjustment mode Notes Most organic painted or oxidized surfaces have emissivity values close to 0 95 The default emis sivity value of the thermometer is set at 0 95 which is suitable for most applications Since the thermometer retains the emissivity setting in its memory always check for ...

Страница 9: ...olished 0 02 0 03 Carbon not oxidized 0 81 Mercury liquid 0 1 Soil 0 90 0 95 Cast Iron 0 44 Mild Steel 0 20 0 32 Steel Oxidized 0 79 Cement 0 54 Mortar 0 87 Steel Polished 0 07 Clay 0 91 Nickel electro plated 0 03 Stainless Steel SS 0 85 Coal 0 8 Nickel polished 0 072 SS polished 0 075 Concrete 0 85 Nickel oxidized 0 59 0 86 Steel Galvanized old 0 88 Concrete rough 0 94 Oak planed 0 89 Steel Galva...

Страница 10: ...ution 0 1 C 0 1 F Response Time Time 500ms Emissivity Adjustable 0 1 1 0 Distance To Spot D S 11 1 Spectral Response 8 14um Diode Laser Class II Power 1mW Wavelength 630 670nm Auto Power Off After 60 seconds of inactivity Operating Temp 0 C to 50 C 32 F to 122 F Storage Temp 20 C to 60 C 4 F to 140 F Relative Humidity RH 10 95 Operating 80 Storage Power Supply 2 pc AA battery Battery Life Typical ...

Страница 11: ...ly to you This warranty gives you specific legal rights and you may also have other rights which vary from province to province FCC INFORMATION Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for Class B digita...

Страница 12: ...0 423 3598 Printed in China Official Licensed Product Vaughan is a registered trademark of Vaughan Bushnell Mfg Co All rights reserved Distribution Returns 2017 Alltrade Tools LLC Reno NV 89508 www vaughangear com MADE IN CHINA ...

Отзывы: