To  6:  "stop timed announcements" < value > "seconds" 

The following values can be set for the interval time (in seconds): 

10 

15 

20 

25 

30 

40 

50 

60 

 

To  7:  "break alarm" < value > "seconds" 

The following values can be set for the interval time (in seconds): 

20 

30 

40 

50 

60 

 

To 

9/10:  "alarm receiver voltage" 

You can select here the digits (1 and 0.1) for the receiver voltage alarm (8). 
The alarm will be triggered if the voltage <= alarm threshold. 

To  13/14:  "divider rotation speed" 

You  can  adjust  the  divider  for  the  RPM  sensor  here  in  order  to  get  a  correct  RPM 
announcement (12), you can adjust the two digits independently. 
When using brushless motors the divider should be half the pole count multiplikated 
with gear ratio. 

To 15:  "announcement altitude in . . . " 

… "Meter" / "Feet" according to setting 44. 
If you set the value to 5,10,20,25 or 50, you will get the current altitude if you press the 
button or if you have timed announcements. Additionally you get an announcement if 
the altitude changes by the set value. 

To 16/17/18:  "alarm altitude" 

You can adjust the alarm altitude in 1000, 100 and 10 m/ft 
The alarm announcement will be triggered when the altitude => alarm threshold 
alarm threshold 0000 m (/ ft) -> no alarm 

To 23:  "vario sound volume" 

The  vario  sound  can  be  adjusted  in  16  steps  in  its  volume.  While  setting  a  tone  is 
generated, which corresponds to the "least falling". 

 
 
 
 

 
 
 

Zu  25/26:  „alarm cell voltage“ 

You can select here the digits (1 and 0.1) for the receiver voltage alarm (24). 
The alarm will be triggered if the min single cell voltage <= alarm threshold. 

To 27:  "announcement speed  in . . . " 

… "km/h" / "mph" according to setting 46. 

To 29:  "announcement current consumption in mAh" 

If you set the value to 100,200,500 or 1000 mAh, you will get the current consumption 
if you press the button or if you have timed announcements. Additionally you will get 
an announcement if the consumption changes by the set value. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 

 

11 

 

12 

 

13 

 

14 

 

15 

 

16 

 

15 

 

14 

 

13 

 

12 

 

11 

 

10 

 

 

 

 

 

 

 

 

 

Содержание VSpeak for JR PROPO

Страница 1: ...n carefully as described in this manual Attention The necessary modifications of the radio will void your warranty With proper implementation of soldering there is no influence of the transmitting rec...

Страница 2: ...ion of the speech module 5 3 0 long key stroke 5 3 1 single click 5 3 2 double click 5 3 3 triple click 5 3 4 Notes on useful settings and operation 9 4 Vario sound 10 5 wav files 10 6 Update 11 7 Acc...

Страница 3: ...y signal XG6 XG8 XG14 XG14E For safety s sake the transmitter battery should be unplugged before soldering Use a soldering iron with a small tip Make sure that you do not short circuit any pins If the...

Страница 4: ...actual readings are announced Values of non connected sensors are not announced even if the setup the relevant announcement on ON position The values are announced according to the order in the table...

Страница 5: ...le click Using single click Button 1 x pressed briefly the regular announcement is started see section 2 1 Is the speech module in mode settings see section 3 3 then by pressing the key the reading sw...

Страница 6: ...rotation speed 0 1 2 3 9 15 announcement altitude in min actual max OFF 5 10 20 25 50 16 alarm altitude 1000 0 1 17 alarm altitude 100 0 1 2 3 9 18 alarm altitude 10 0 1 2 3 9 19 announcement rising o...

Страница 7: ...saved To 1 VSpeak settings There are 3 sets of different parameters available You can change the parameter sets here easily To 2 selection language german english french spanish czech Russian portugue...

Страница 8: ...if you press the button or if you have timed announcements Additionally you get an announcement if the altitude changes by the set value To 16 17 18 alarm altitude You can adjust the alarm altitude in...

Страница 9: ...nts they are only saved now at this point if no changes were made this announcement is not applicable Accidental or incorrect entries can thus be discarded by switching off the radio before reaching t...

Страница 10: ...15 14 3 2 For a long climb passages e g E gliders F trail or just during gymnastics can the Vario sound be switched OFF and the ON again by double clicking 2x short activation 5 wav files The wav fil...

Страница 11: ...eiver speaker BT devices 1 Wired earphones www conrad com article no 386308 in our opinion the best price performance ratio 2 Hama mini speaker www conrad com article no 343151 3 Wireless via Bluetoot...

Страница 12: ...formation technology equipment Safety EN61000 6 1 Electromagnetic compatibility EMC EN61000 6 3 EN55022 Information technology equipment Radio disturbance characteristics Priestewitz 2014 06 01 Signat...

Страница 13: ...XG6 www VSpeak modell de Page 1 1 XG6 9 mm 9 mm 10 mm 7 mm 10 mm 6 mm...

Страница 14: ...Page 1 1 XG8 XG14 XG8 and XG14 are almost identical in both the housing dimensions and the plug assembly on the PCB so the representations are here using the example of a XG8 valid for the XG14 too 10...

Страница 15: ...XG11 www VSpeak modell de Seite 1 1 XG11 Installation description from a XG11 pilot http www modelbouwforum nl threads vspeak inbouwen in xg11 jr propo 241394...

Страница 16: ...dge of the hole has to reduced carefully by hand rotating 9mm twist drill Due to the installation height of the VSpeak module and the arrangement of the housing locking the VSpeak module can only be f...

Отзывы: