VS Security Products LTD
ZZ201220, ZZ201222
Page 23 of 25
10.6 Archive File Format
The archive file format is a
c
omma
s
eparated
v
ariable file. Each field in the record is separated (de
-
limited) from the next
field by a comma. The fields contain alpha numeric text. A comma is not allowed within a field.
The fields in the record are as follows:
Field
Contents
=====
========
01
-
Record Number (Numeric starting at 1)
02
-
Date
03
-
Time
04
-
Machine Type
05
-
Machine Model
06
-
Machine SN
07
-
Machine FW
08
-
Machine Number of Cycles
09
-
Company Name
10
-
Operator
11
-
Supervisor
12
-
Site
13
-
Media Owner
14
-
Media Department
15
-
Media Type
16
-
Media Info SN
17
-
Media Info Capacity
18
-
Media Info PN
19
-
Media Info Class
20
-
Media Info Remarks
21
-
Capacitor Voltage (Volts)
22
-
Magnetic Field Strength (Gauss)
23
-
Result (Degaussed, Crushed, Failed etc.)
SECTION 11: SAFETY RECOMMENDATIONS
Gloves
It is recommended that suitable protective gloves are worn when handling the crushed media or debris in order to protect
hands from sharp edges.
Swarf
It recommended that the Debris Collection Tray is emptied frequently to prevent the build up of swarf inside the Crunch 250.
SECTION 12: MAINTENANCE
12.1 Resetting the circuit breaker
The Crunch 250 Degasser is not equipped with any on
-
board fuses that require replacement. All the systems within the unit
are protected by the circuit breaker which is located on the rear of the unit –
this can be manually reset by the user.
If the unit fails in any way, the user should verify the condition of the circuit breaker prior to contacting support.
The Crunch 250 contains mains voltages and currents. For safety reasons, VS Security Products Ltd does not
recommend that the covers be removed by anyone other than trained VS Security Products technicians.
Cleaning
Excess dust or debris should be regularly cleaned from the Destruction Chamber and Guide Rails using either a cloth and/or
by vacuuming. The outside of the unit may be wiped with a soft cloth but no harsh cleaning agents should be used.