5.4 Using Trigger and Strobe
Depending on your camera model, the pins for trigger and strobe are located on dif-
ferent connectors. The following tables show the different connectors and the cor-
responding pinouts for trigger and strobe. If you are not sure about the location of the
connectors, please refer to
Â
2.2 on page 10.
Single-Sensor Housing Cameras
Camera models: VRm(F)C-X-PRO
Connector
Pin
Signal
1
11
12
21
MPE Garry Micro-T 386-2-021-ZS0
1
GND
2
Passive Strobe Out – (3...24 V)
3
Passive Strobe Out + (3...24 V)
4
Active Strobe Out (+5 V)
5
GND
6
Passive Trigger In – (3...24 V)
7
Passive Trigger In + (3...24 V)
8
Active Trigger In (+3.3...5 V)
9
GND
10...11
+5 V
12...21
...
Single-Sensor Board-Level Cameras, Remote-Sensor Cameras, Multi-Sensor
Cameras
Camera Models: VRm(F)C-X-OEM/COB, VRmC-X-E, VRmMFC
Connector
Pin
Signal
1
15
Hirose DF14-15P
1...2
+5 V
3
GND
4...7
reserved
8
GND
9
Active Trigger In (+3.3...5 V)
10
Active Strobe Out (+5 V)
11...12
reserved
13
GND
14...15
reserved