PAGE: 9

LP-41   REV:  3/1/03

SSVH MODEL PERFORMANCE AND SET-UP INFORMATION

The SSVH models are available in the 90,000 BTU/hr, 130,000, and 199,000 BTU/hr. firing rates.  The illustration on 

page 43

show the

location of the heat exchanger and other ports.  For maximum output, the bronze circulator provided must be attached between the hot
outlet and cold inlet as shown on 

page 22

.  For complete SSVH information and sizing, refer to 

pages 42 and 43

.

CONTROL DESCRIPTION

The fully integrated water heater control is an all electronic, fully automatic controller which will provide many years of trouble free ser-
vice.  The control requires no periodic maintenance and includes a built-in microprocessor which performs a number of diagnostic tests
to verify proper appliance and control operation. Should an unsafe condition occur, the burner will shut down and the appropriate status
indicators will illuminate indicating the need for service.  Consisting of two printed circuit board assemblies, the controller's main board
is attached to inside left of the shroud while the display board is mounted to the front top of the shroud. This arrangement simplifies
access to the user adjustments while enhancing the visibility of the temperature display and status indicators.  A power step-down
transformer and blower pressure switch are also mounted on the inside left of the shroud.  The controller display functions include a
high visibility three digit LED readout which is used to display the actual water temperature within the tank along with the programmed
desired water temperature (set point temperature).  Nine individual LED indicators are also mounted on the display board which are
used to determine the operating status of the appliance and provide assistance when troubleshooting any problems which may occur.
All indicators are of the solid state variety and should last for the life of the appliance.  The controller has sufficient built-in memory to
retain the programmed temperature set point in the event input power is ever interrupted.  The final component of the control system
includes a temperature sensing probe which is threaded into the side of the tank.  This probe is of unique construction in that both the
temperature sensing/control and safety limit functions are performed by this single device.  All probe components are of solid state con-
struction to provide extended operational life.

START UP PROCEDURE

1.  

Make sure that the Voyager has been installed to these instruction procedures; along with all applicable province and local 
codes;

2.  

Make sure all gas piping and connections have been verified and inspected by all applicable inspectors.  Turn on gas supply.  
Insure that the gas line and the LP tank, if applicable, have been properly purged.  Failure to properly purge the gas lines will 
result in failure to operate;

3. 

Make sure that the cold water supply has been turned on and that the Voyager is completely filled with water.  Verify this by 
opening a hot water faucet, and allowing water to flow until all air is removed and a clear water flow is present;

4.  

Turn on electrical supply;

5. 

The control will first display "102", then "88.8", which is the control display test; and finally the actual tank temperature at the 
probe.

SET POINT ADJUSTMENT PROCEDURE

The three digit LED display will illustrate actual water temperature within the tank under normal operating conditions.  However, this
display is also used to indicate the temperature set point when in the programming mode; and also ignitor amp draw and flame current.

The controller has a temperature set point range 70 degrees F. to 160 degrees F.  The factory set point is 118 degrees F.

VERY IMPORTANT NOTE:

POWER MUST BE APPLIED TO THE CONTROLLER PRIOR TO ANY PROGRAMMING OPERATIONS.

Содержание SSV100-45R

Страница 1: ...AS FIRED WATER HEATING COMBINATION APPLIANCE ANSI Z 21 10 3 MANUFACTURED BY HEAT TRANSFER PRODUCTS INC P O BOX 429 120 BRALEY ROAD EAST FREETOWN MA 02717 TEL 1 508 763 8071 and outside of MA 1 800 323...

Страница 2: ...6 SSV130 80R 23 1 4 230 Lbs 32 SSV130 45R 23 1 4 175 Lbs 32 SSV100 45R 23 1 4 175 Lbs 32 SSV90 45S 23 1 4 175 Lbs 32 74 72 27 1 4 27 1 4 42 1 2 72 42 1 2 42 1 2 74 42 1 2 42 1 2 FIRST HOUR VENT RECOVE...

Страница 3: ...esult in damage to the surrounding areas or to the lower floors of the building A water heater should always be located in a area with a floor drain or installed in a drain pan suitable for water heat...

Страница 4: ...be performed by a qualified licensed electrician and in accordance with National Electrical Code or to the applicable local codes and standards The electrical requirements are for standard 120 volts 6...

Страница 5: ...as per local and national standard plumbing codes It is important that the piping must be clean and free from burs debris ragged ends and particles of PVC For exhaust piping lower pipe on the right o...

Страница 6: ...5 for ABS or ASTM F 441 for CPVC and fittings to ASTM D2661 D3311 for ABS and ASTM F 439 for CPVC the balance of exhaust piping and all of intake piping use standard 3 PVC sch 40 or 3 ABS schedule 40...

Страница 7: ...FEET FOR EACH ELBOW TOTAL FRICTION LOSS FOR ELBOWS GRAND TOTAL VENT LENGTH FEET WITH FITTING FRICTION LOSS ADDED 12 2 5 10 22 20 2 5 10 30 20 3 5 15 35 20 4 5 20 40 20 5 5 25 45 20 6 5 30 50 20 7 5 3...

Страница 8: ...the entire intake system providing it conforms to ASTM F 891 and is cemented together using above materials never use foam core pipe for the exhaust pipe VERY IMPORTANT SSV100R SSV130R MODELS ONLY Al...

Страница 9: ...g any problems which may occur All indicators are of the solid state variety and should last for the life of the appliance The controller has sufficient built in memory to retain the programmed temper...

Страница 10: ...g the set point button when power is applied to the control Shut off power to the control Next hold in the set point button Now reapply power to the control Using the set point button the value of the...

Страница 11: ...the set point to 70 degrees F DO NOT turn off electrical power If there is no danger of freezing follow the Shutdown Procedure FAILURE TO OPERATE Should the burner fail to light the control will perfo...

Страница 12: ...PAGE 12 LP 41 REV 3 1 03...

Страница 13: ...g ori fices This is only a guide to correct orifice sizing If orifices are drilled the result will be poor ignition a VOIDED WARRANTY severe bodily injury death and or explosion All orifices must be o...

Страница 14: ...UTPUT IS ENERGIZED POWER APPLIED TO BLOWER IGNITOR MONITORS IGNITOR ELEMENT OUTPUT ON WHEN OUTPUT IS ENERGIZED POWER APPLIED TO IGNITOR 24V MONITORS INCOMING VOLTAGE FROM THE ON WHEN SECONDARY VOLTAGE...

Страница 15: ...PAGE 15 LP 41 REV 3 1 03...

Страница 16: ...PAGE 16 LP 41 REV 3 1 03...

Страница 17: ...PAGE 17 LP 41 REV 3 1 03...

Страница 18: ...PAGE 18 LP 41 REV 3 1 03...

Страница 19: ...PAGE 19 LP 41 REV 3 1 03...

Страница 20: ...PAGE 20 LP 41 REV 3 1 03 TYPICAL VENTING...

Страница 21: ...PAGE 21 LP 41 REV 3 1 03...

Страница 22: ...PAGE 22 LP 41 REV 3 1 03...

Страница 23: ...PAGE 23 LP 41 REV 3 1 03...

Страница 24: ...PAGE 24 LP 41 REV 3 1 03...

Страница 25: ...PAGE 25 LP 41 REV 3 1 03...

Страница 26: ...HARNESS FROM THE GAS VALVE BY PRESSING ON THE TABS ON THE TOP AND BOTTOM OF THE PLUG AND PULLING 13 REMOVE THE TWO GREEN GROUNDING WIRES FROM THE TOP REAR OF THE BLOWER BY TAKING OUT THE GREEN GROUNDI...

Страница 27: ...PART 99MA 5 RE INSERT THE BURNER WITH THE FLAT SIDE OF THE FLANGE FACING DOWN 6 REPLACE THE BLOWER OUTLET FLANGE GASKET WITH A NEW GASKET BE SURE THAT BOTH SIDES OF THE GASKET ARE SPRAYED WITH PERMAT...

Страница 28: ...7 16 DEEP SOCKET 19 PLACE GAS ORIFICE ON TOP OF THE SPLIT UNION WITH HOLE FACING UP AS SHOWN BELOW 20 RE CONNECT THE GAS VALVE TO THE AIR INLET MANIFOLD BY TURNING THE UNION COUNTER CLOCKWISE AND TIG...

Страница 29: ...PAGE 29 LP 41 REV 3 1 03 PARTS ILLUSTRATIONS AIR INLET ADAPTER NI110 AIR INLET MANIFOLD A5000...

Страница 30: ...PAGE 30 LP 41 REV 3 1 03 GASKET AIR INLET G5030 GAS ORIFICE UNION GGU5...

Страница 31: ...PAGE 31 LP 41 REV 3 1 03 GAS ORIFICE 01000 AIR ORIFICE A3001 1 0 SIZE A3002 1 125 SIZE A3003 1 375 SIZE FLAME RECTIFICATION PROBE PSE TF1...

Страница 32: ...PAGE 32 LP 41 REV 3 1 03 GASKET BURNER MOUNTING FLANGE G5010 BURNER MOUNTING FLANGE 7000 616...

Страница 33: ...PAGE 33 LP 41 REV 3 1 03 GAS VALVE GV1000 AIR INLET CONNECTOR F3000...

Страница 34: ...PAGE 34 LP 41 REV 3 1 03 110V IGNITOR SURFACE IGNITER 0206FF003 GASKET BURNER MOUNTING FLANGE WHITE G5040 GASKET BLOWER OUTLET FLANGE G5020...

Страница 35: ...ETWEEN THE GAS VALVE AND AIR INLET REMOVE OLD GAS ORIFICE 5 AND INSTALL THE NEW GAS ORIFICE IN THE UNION THAT CORRESPONDS TO THE UNIT MODEL NUMBER AND FUEL BEING USED SEE KIT CONTENT LIST FOR THE CORR...

Страница 36: ...HE VOYAGER 2 REMOVE THE DOOR FROM THE VOYAGER CABINET 3 SHUT OFF THE GAS VALVE BY TURNING THE BLUE KNOB ON THE VALVE TO THE OFF POSITION 4 SHUT OF THE GAS SUPPLY TO THE VOYAGER 5 BREAK THE UNION ON TH...

Страница 37: ...RS AVAILABLE THEN FOLLOW INSTALLATION PROCEDURE 2 IF NO MANOMETERS ARE AVAILABLE USE INSTALLATION PROCEDURE 1 PROCEDURE 1 1 RE CONNECT THE GAS VALVE WIRING HARNESS TO THE GAS VALVE 2 SLIDE THE GAS VAL...

Страница 38: ...ND THE GAS VALVE WIRING HARNESS IS PLUGGED INTO THE GAS VALVE AND INTO THE CONTROL BOARD 2 TURN THE ADJUSTMENT SCREW UNDER THE BRASS CAP YOU REMOVED IN STEP 8 ABOVE TURN ONE FULL TURN CLOCKWISE WITH A...

Страница 39: ...E STEADIES 2 PUT THE GAS VALVE ADJUSTMENT SCREW COVER BACK IN PLACE AND TIGHTEN 3 PUT THE VOYAGER CABINET DOOR BACK INTO PLACE PROCEDURE 2 1 REMOVE THE OUTLET PRESSURE TAP PLUG FROM THE RIGHT SIDE OF...

Страница 40: ...RE CONNECT THE SUPPLY GAS PIPING TO THE VALVE 8 TURN ON THE GAS TO THE VOYAGER 9 TURN THE BLUE KNOW ON THE GAS VALVE TO ON 10 REMOVE THE SMALL ROUND BRASS PLUG FROM THE GAS VALVE BY TURNING IT COUNTE...

Страница 41: ...NOT LIGHT OFF TURN THE ADJUSTMENT SCREW TWO FULL TURNS COUNTERCLOCKWISE 14 SHUT THE VOYAGER DOWN THEN START IT UP AGAIN LET IT RE LIGHT IF THE IGNITION WAS GOOD THE VALVE NEEDS NO FURTHER ADJUSTMENT...

Страница 42: ...ON GASES AND CONNECTION OF A BRONZE CIRCULATOR BETWEEN DOMESTIC HOT WATER OUTLET DOMESTIC COLD WATER INLET NOTE IT IS VERY IMPORTANT TO FOLLOW EITHER LOCAL OR FEDERAL PLUMBING CODES WHEN INSTALLING AN...

Страница 43: ...400 95 200 119 000 124 500 10 85 000 113 250 140 000 140 000 FOR SSVH 130 MODELS ONLY FOR SSVH 199 80 MODELS ONLY NOTE THE VOYAGER MUST BE SET 25 DEGREES F ABOVE THE SYSTEM TEMPERATURE THE ABOVE CHAR...

Страница 44: ...S VENT SIZED FROM 3 TO 4 BY USING BUSHINGS INSTEAD OF REDUCING COUPLING OR REDUCING ELBOW VENT CHANGED FROM 3 TO 4 WITHOUT GOING REQUIRED 10 ON BOTH INTAKE AND EXHAUST VENTING NOT CLEANED AND GLUED TO...

Отзывы: