![Voyager SSV100-45R Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/voyager/ssv100-45r/ssv100-45r_operating-manual_1052292043.webp)
PAGE: 43
LP-41 REV: 3/1/03
EXHAUST
CONDENSATE
DRAIN
IN
COLD
OUTLET
CONDENSATE
DRAIN
COLD IN
VOYAGER
GAS INLET
AIR INLET
STAINLESS STEEL HIGH EFFIENCY WATER HEATER
CONTROL
HOT OUT
T&P
ELECTRICAL
CONNECTION
GAS
CONTROL
HOT OUT
(SSVH
MODELS
ONLY)
OPTIONAL
HEAT
EXCHANGER
INLET
K
N
P
O
B
C
D
E
G
H
J
L
A
M
Q
R
I
F
VOYAGER DIMENSIONS *
A
B
C
D
E
F
G
H
I
23 1/4"
42 1/2"
18 1/2"
6"
35 1/4"
34 1/2"
25 1/2"
5 1/4"
3 3/4"
23 1/4"
72"
20"
64"
37"
27 1/4"
7 1/2"
5 1/2"
5 1/4"
27 1/4"
66 1/2"
22 1/4"
74"
9 3/4"
7 1/2"
7 3/4"
29 1/2"
40 1/2"
45 GAL.
80 GAL.
119 GAL.
31 1/4"
K
31 1/4"
27 1/4"
L
27 1/4"
25 3/4"
J
25 3/4"
35 1/4"
31 1/4"
29 3/4"
N/A
60 3/4"
N
33 3/4"
5 1/4"
M
N/A
5 1/2"
O
21 1/2"
23 1/4"
25 1/2"
33 1/2"
64"
66 1/2"
P
32"
28 1/4"
Q
29 3/4"
R
15"
15"
15"
NOTE:
A BRONZE CIRCULATOR BETWEEN THE DOMESTIC HOT WATER OUTLET AND DOMESTIC COLD WATER INLET IS
REQUIRED TO ACHIEVE RATINGS BELOW:
VOYAGER SSVH MODEL SIZING CHART
Flow
TEMPERATURE RISE (DEGREES F.)
GPM
15
20
25
30
2
15,000
20,000
25,000
30,000
3
22,500
30,000
37,500
45,000
4
30,000
40,000
50,000
60,000
5
37,500
50,000
62,500
75,000
6
45,000
60,000
75,000
90,000*
7
52,500
70,000
87,500*
105,000*
8
60,000
80,000
100,000*
N/R
9
71,400**
95,200**
119,000**
124,500**
10
85,000**
113,250**
140,000**
140,000**
* FOR SSVH-130 MODELS ONLY! **FOR SSVH-199-80 MODELS ONLY!
NOTE:
THE VOYAGER MUST BE SET 25 DEGREES F. ABOVE THE SYSTEM TEMPERATURE. THE ABOVE CHART IS BASED ON
USING THE CIRCULATOR BETWEEN THE DOMESTIC COLD WATER INLET AND THE DOMESTIC HOT WATER OUTLET. FOR
SET POINT TEMPERATURES ABOVE 120 DEGREES F., YOU MUST USE AN ANTI-SCALD TEMPERING VALVE ON THE OUT-
LET TO DOMESTIC HOT WATER FIXTURES.
VOYAGER FIRST DRAW CAPACITY (In minutes) AT 140 DEGREES F.
Model
2 GPM
3 GPM
4 GPM
5 GPM
6 GPM
7 GPM
8 GPM
SSVH90-45
20
15
9
7
5
4
3
SSVH130-45
20
16
12
10
9
7
6
SSVH199-80
00
00
15
14
13
12
10
VOYAGER FIRST DRAW CAPACITY (In minutes) AT 115 DEGREES F.
Model
2 GPM
3 GPM
4 GPM
5 GPM
6 GPM
7 GPM
8 GPM
SSVH90-45
30
23
14
10
8
6 5
SSVH130-45
31
24
18
16
14
11
10
SSVH199-80
00
00
23
21
20
18
15
MODEL
HEIGHT
WIDTH
DEPTH
INPUT
FIRST HR. RATING
SSVH90-45
42"
24"
32"
90,000
125 U.S. gallons
SSVH130-45
42"
24"
32" 130,000
180 U.S. gallons
SSVH199-80
72"
24"
32" 199,000
300 U.S. gallons
MODEL
HEAT EXCH.
HEAT EXCH. BTU
RECOVERY
VENT
WEIGHT
SSVH90-45
32 Sq. Ft.
81,000
95%
3"
205 Lbs.
SSVH130-45
32 Sq. Ft.
110,000
94%
3"
205 Lbs.
SSVH199-80
32 Sq. Ft.
140,000
94%
3"
255 Lbs.
Note: These overall dimensions are approximate /– 1".
Heat Transfer Products reserves the right to change or discontinue models without notice.
Содержание SSV100-45R
Страница 12: ...PAGE 12 LP 41 REV 3 1 03...
Страница 15: ...PAGE 15 LP 41 REV 3 1 03...
Страница 16: ...PAGE 16 LP 41 REV 3 1 03...
Страница 17: ...PAGE 17 LP 41 REV 3 1 03...
Страница 18: ...PAGE 18 LP 41 REV 3 1 03...
Страница 19: ...PAGE 19 LP 41 REV 3 1 03...
Страница 20: ...PAGE 20 LP 41 REV 3 1 03 TYPICAL VENTING...
Страница 21: ...PAGE 21 LP 41 REV 3 1 03...
Страница 22: ...PAGE 22 LP 41 REV 3 1 03...
Страница 23: ...PAGE 23 LP 41 REV 3 1 03...
Страница 24: ...PAGE 24 LP 41 REV 3 1 03...
Страница 25: ...PAGE 25 LP 41 REV 3 1 03...
Страница 29: ...PAGE 29 LP 41 REV 3 1 03 PARTS ILLUSTRATIONS AIR INLET ADAPTER NI110 AIR INLET MANIFOLD A5000...
Страница 30: ...PAGE 30 LP 41 REV 3 1 03 GASKET AIR INLET G5030 GAS ORIFICE UNION GGU5...
Страница 32: ...PAGE 32 LP 41 REV 3 1 03 GASKET BURNER MOUNTING FLANGE G5010 BURNER MOUNTING FLANGE 7000 616...
Страница 33: ...PAGE 33 LP 41 REV 3 1 03 GAS VALVE GV1000 AIR INLET CONNECTOR F3000...