Use connecting bolts for all steel wire connections to ensure a good circuit is made.

To ensure correct functionality, ground the energiser using grounding posts made of 
galvanised metal.

Use double-insulated cable inside buildings, under driveways and in places where any 
galvanised wires lying on the ground may become corroded, Never use household 
electrical cables as these are designed to carry 600 volts at most and a loss of current 
may occur.

 

ELECTRIC FENCE REQUIREMENTS

Electric fences and associated equipment must be constructed and operated and main-
tained such that there is no danger to people, animals and their surroundings. Electric 
fences in which people or animals can get caught must be avoided. An electric fence 
may not be supplied by two separate energisers or by independent fence circuits from 
the same energiser.
 
Where there are two separate electric fences, each supplied by a separate energiser, 
the distance between the wires of the fences must be at least 2.5 m. If this gap between 

the fences must be closed off, then this must be done using non­conducting materials 
or an insulated metal barrier. Barbed wire or sharp edged wire may not be electrified 

by an energiser.
 

Observe the manufacturer’s recommendations for grounding the energiser.

A distance of at least 10 m must be kept between the grounding electrode for the en-
ergiser and any other components connected to a grounding systems (e.g. the ground 
connections for power supply systems or telecommunications systems). Connecting 

cables that run through buildings must be effectively isolated from grounded parts of 

the building. This can be achieved using insulated high-voltage cables. 

If connection cables and wires that are part of the electric fence must run near to 
high-voltage cables, then they may not be installed more than 3 m above the ground. 
This height applies to each side of a right-angled projection from the outer conductor  
of the high-voltage cable on the area for a distance of 

• 2 m for high-voltage lines that operate at a rated voltage of up to 1000 V;

• 15 m for high-voltage lines that operate at a rated voltage over 1000 V. 

Electric fences intended for scaring off birds, for keeping pets or training animals, 

 

e.g. cows (cow trainer), should only be supplied by an energiser at low power (which  

still has a sufficient and secure effect). Where an electric fence is intended to prevent 

birds from nesting on buildings, no wire of the electric fence may be grounded if the 
fence wires are not connected to metal parts. If a wire is connected to a metal part  
(e.g. gutter) or a metal structure in the building, then this metal part must be  
grounded. A warning sign must be attached at all points where people are able  
to freely access the conductors.

Where an electric fence crosses a public footpath, a non­electrified gate or stile must 
be present. Each of these stiles must be fitted with warning signs indicating that the 

fence is an electric fence. Each part of an electric fence that runs along public streets  
or other rights of way must have warning signs securely attached to fence posts or  
the wires at regular intervals.

Connecting wires that run below the ground must be placed inside protective  
insulated pipes or use insulated high-voltage cables. It is important to ensure that  

connecting cables cannot be damaged by external influences (e.g. animals hooves, 

tractor wheels, etc.) that make indentations in the soil. Connecting lines may not be 
installed in the same protective pipes as mains and supply cables, communication  
or data lines. Connecting cables and wires belonging to electric fences may be laid 
above high-voltage or communications cables. Crossing high-voltage cables should  
be avoided. If crossing over a high-voltage cable cannot be avoided, then the  
connection must be laid below the high-voltage cable and be as close to a right- 
angle with it as possible. 

Warning signs must be at least 100 x 200 mm in size. The background colour on both 
sides of the warning sign must be yellow. The text on the warning sign must be black. 
The text must read “Warning: Electric Fence”. The text on the warning sign must be 
printed in a durable way and be at least 25 mm in height. Ensure that all mains- 
powered supporting equipment connected to the electric fence circuit has a degree  
of insulation between the fence circuit and mains supply corresponding to the energiser.

9. DISPOSAL

If you wish to dispose of the energiser, please contact a local disposal company or 
recycling centre. Alternatively, you may contact VOSS GmbH. All consumers are legally 
required to properly dispose of old electronic devices. Please do not dispose of the 
energiser with your normal household waste. This helps make a valuable contribution 
to protecting our environment.

Содержание Fenci M03

Страница 1: ...DE UK SE NL FR VOSS PET fenci M03 M05 M09 Elektrozaunger t Energiser Elst ngselaggregat Schrikdraadapparat lectrificateur de cl ture...

Страница 2: ...VOSS PET fenci 41205 fenci M03 41210 fenci M05 41215 fenci M09 VOSS GmbH Co KG Ohrstedt Bhf Nord 5 25885 Wester Ohrstedt Service VOSS GmbH Co KG Logistics Centre Ole Bahndamm 2 D 25884 Vi l Art Nr VO...

Страница 3: ...Hund oder Ihre Katze h tesicher einz unen m chten Die hochwertige Verarbeitung und Entwicklung erfolgt nach modernsten Standards und Sicherheitsvorschriften was Ihnen einen gefahrlosen Betrieb garant...

Страница 4: ...Nr 41150 Dadurch kann das Ger t an eine handels bliche Hutschiene montiert werden Das VOSS PET fenci h lt allen Witterungsbedingungen stand wie z B Regen Spritz wasser Sonneneinstrahlung hohen Tempera...

Страница 5: ...rbesserung der Erdung Als Verbindungskabel zwischen den Erdpf hlen empfehlen wir Art Nr 33615 Wenn Sie f r eine optimale Erdung sorgen erreicht das VOSS PET fenci seine volle Leistungsst rke und Sie e...

Страница 6: ...enci immer aus und trennen Sie es von der Stromzufuhr wenn Sie Wartungs oder Reinigungsarbeiten am Ger t vornehmen Das Ger t arbeitet wartungsfrei dennoch sollten Sie regelm ig Sichtkontrollen durchf...

Страница 7: ...endung isolierter Hochspannungsleitungen erreicht werden Falls Anschlussleitungen und Dr hte von Elektroz unen in der N he von Hochspan nungsleitungen installiert sind darf deren H he ber dem Boden 3...

Страница 8: ...nicht mit Metallteilen verbunden sind Wenn ein Draht mit einem Metallteil z B der Dachrinne oder einer Metallstruktur des Ge b udes verbunden ist muss dieses Metallteil geerdet sein Ein Warnschild mu...

Страница 9: ...50 V 1 6 km 2 km 0 5 km 41210 fenci M05 0 4 J 0 3 J 2500 V 1 12 km 5 km 3 km 41215 fenci M09 0 8 J 0 6 J 3000 V 1 21 km 7 km 5 km 1 Mains plug 230 volts 2 Indicator LED Energiser working blue light Ch...

Страница 10: ...cares the animal away The electrical circuit is completed through the ground It is not necessary to created a closed fence system The fence can end at any point 3 ASSEMBLY AND CONNECTION Install the e...

Страница 11: ...n operate at its maximum capacity and ensure your fence provides the best possible security TIP Where soil conditions are poor with low conductivity we recommend using an additional 2 or 3 grounding p...

Страница 12: ...ly on a regular basis Check all cables and lines for damage Contact a specialist immediately to replace any broken parts or cables Do not operate the energiser if there is any damage Keep the energise...

Страница 13: ...y replacement parts authorised by the manufacturer may be used OPERATING PRINCIPLE AND LIMITS OF ELECTRIC FENCES FOR ANIMALS An electric fence consists of an energiser and an insulated fence The energ...

Страница 14: ...energiser at low power which still has a sufficient and secure effect Where an electric fence is intended to prevent birds from nesting on buildings no wire of the electric fence may be grounded if th...

Страница 15: ...by visiting http voss group eu certificate DE Originalbetriebsanleitung Elektrozaunger t EN Operating Instructions Energiser SE Bruksanvisning Elst ngselaggregat NL Gebruiksaanwijzing Schrikdraadappa...

Страница 16: ...ngerar tillsammans med VOSS PET fenci p ett tillf rlitligt och optimalt s tt 2 HUR FUNGERAR ETT ELST NGSEL VOSS PET fenci utg r st ngslets viktigaste komponent och uts nder str mpulser med j mna mella...

Страница 17: ...r all p frestning fr n v der och vind t ex regn eller vatten st nk solsken h ga temperaturer och frost Vi rekommenderar att VOSS PET fenci monteras p en plats som r skyddad mot v der och vind t ex en...

Страница 18: ...4214 eller 44219 Om marken r torr eller st ngslet r l ngt b r du placera flera jordp lar p ca 2 3 m avst nd f r att f rb ttra jordningen Som f rbindelsekabel mellan jordp larna rekommenderar vi art nr...

Страница 19: ...nspekteras regelbundet Kontrollera regelbundet att inga kablar eller ledningar r skadade Trasiga delar eller kablar m ste omedelbart bytas ut av en yrkesutbildad person Ta inte aggregatet i drift om d...

Страница 20: ...ras i n rheten av h gsp nningsledningar f r dessa inte befinna sig h gre n 3 m ver marken Denna niv g ller f r varje sida av den rektangul ra projektionen av ELST NGSLETS EFFEKT OCH BEGR NSADE EFFEKT...

Страница 21: ...t ller som kan n s av personer med hj lp av stegar Om ett elst ngsel korsar en offentlig g ngv g m ste elst ngslet f rses med en icke str mf rande grind eller en st ngsel verg ng Alla verg ngar m ste...

Страница 22: ...10 fenci M05 0 4 J 0 3 J 2500 V 1 12 km 5 km 3 km 41215 fenci M09 0 8 J 0 6 J 3000 V 1 21 km 7 km 5 km 1 Stekker 230 Volt 2 Controle led Werking apparaat blauw licht Controle omheining minder dan 3 00...

Страница 23: ...aarlijke elektrische schok wordt door het dier als onaangenaam waargenomen Dit zorgt voor het gewenste afschrikeffect De stroomkring wordt via de aarde gesloten Het is niet nodig dat u een volledig ge...

Страница 24: ...imale aarding zorgt behaalt de VOSS PET fenci zijn volledige vermogen en bereikt u de best mogelijke beveiliging aan de omheining TIP Wij adviseren om bij een slecht geleidende ondergrond 2 tot 3 extr...

Страница 25: ...schadigingen Laat kapotte onderdelen of kabels direct door een specialist vervangen Gebruik het apparaat niet als er beschadigingen aanwezig zijn U kunt het apparaat schoonmaken door het met een licht...

Страница 26: ...worden uitgevoerd Er mogen uitsluitend door de fabrikant voorgeschreven vervangende onderdelen worden gebruikt WERKING EN GRENZEN VAN EEN ELEKTRISCHE OMHEINING VOOR DIEREN Een elektrische omheining b...

Страница 27: ...nste geleider van de hoogspanningskabels op het oppervlak voor een afstand van 2 m bij hoogspanningskabels met een nominale spanning van ten hoogste 1000 V 15 m bij hoogspanningskabels met een nominal...

Страница 28: ...aties met netstroom die op de stroomkring van de elektrische omheining zijn aangesloten een isolatiegraad tussen het circuit van de omheining en de stroomvoorziening bieden die overeenkomt met die van...

Страница 29: ...l ture lectrique fonctionne de mani re fiable et optimale en liaison avec le VOSS PET fenci 2 COMMENT FONCTIONNE UNE CL TURE LECTRIQUE Le VOSS PET fenci est la pi ce ma tresse de votre cl ture Elle pr...

Страница 30: ...u courant dans le commerce Le VOSS PET fenci est r sistant aux intemp ries telles que la pluie les projections d eau les rayons du soleil les hautes temp ratures et le gel Nous vous conseillons de pla...

Страница 31: ...ou 44219 servent de piquets de mise la terre En cas de sol sec et de longue cl ture placez d autres piquets de mise la terre espac s d environ 2 3 m pour am liorer la mise la terre Comme c ble de liai...

Страница 32: ...i vous devez faire des interventions de maintenance ou de nettoyage sur l appareil L appareil fonctionne sans entretien cependant vous devez effectuer r guli rement des contr les visuels Contr lez r g...

Страница 33: ...te ten sion isol es Si les lignes de raccordement et les fils des cl tures lectriques sont install s pr s des lignes haute tension leur hauteur ne doit pas d passer 3 m du sol Cette hauteur MODE D ACT...

Страница 34: ...nicher sur des b timents aucun fil de la cl ture ne doit tre mis la terre si les fils de la cl ture ne sont pas reli s des pi ces en m tal Si un fil est reli avec une partie m tal lique par exemple la...

Страница 35: ...VOSS GmbH Co KG Ohrstedt Bhf Nord 5 D 25885 Wester Ohrstedt...

Отзывы: