10
ENGLISH
Remote Control Control Panel
Fig. 1
The appliance is controlled via wired Remote Control.
The Remote Control manages from 1 to 6 devices. The Control panel is equipped with the following controls (fig.1):
Buttons:
= button SPEED;
= button MODE;
= button BOOST;
LEDs:
①
= LED 1 = SPEED 1 (white);
②
= LED 2 = SPEED 2 (white);
③
= LED 3 = SPEED 3 (white);
④
= LED 4 = SPEED 4 (white);
⑤
= LED 5 = LED EXTRACTION (white);
⑥
= LED 6 = LED VENTILATION (white);
⑦
= LED 7 = LED RECOVERY (white);
⑧
= LED 8 = LED FILTER (red);
⑨
= LED 9 = LED BOOST (blue).
•
= SPEED button: airflow selector
Press repeatedly to select speeds:
- 0: Stand-by/fans off
(LED 1+ LED 2 + LED 3 + LED 4: off)
;
- 1: Minimum flow rate
(LED 1: on);
- 2: Average flow rate
(LED 1 + LED 2: on);
- 3: High flow rate
(LED 1 + LED 2 + LED 3: on);
- 4: Maximum flow rate
(LED 1 + LED 2 + LED 3 + LED 4: on);
•
= MODE button: fan mode selector
Press repeatedly to select modes:
- RECOVERY
(LED RECOVERY: on);
- VENTILATION
(LED VENTILATION: on);
- EXTRACTION
(LED EXTRACTION: on).
• = BOOST button: max speed selector
Press repeatedly to select modes:
- BOOST on
(BOOST LED +
LED 1 + LED 2 + LED 3 + LED 4: on
);
- BOOST off
(BOOST LED +
LED 1 + LED 2 + LED 3 + LED 4: off
).
Heat recovery mode
Winter: Extracted air from the room (hot) is exploited to pre-heating the air supplied to the room (cold).
Summer: Extracted air from the room (cold) is exploited to pre-cooling the air supplied to the room (hot).
The connected devices cyclically reverse the direction of fan rotation (extracting and introducing air into the environment)
with a set cycle time.
Speed adjustment (of devices) is automatic and ensures the correct balance of the Input/Output flow rates.
Further information on cycle time is provided in the paragraph "Setting operating parameters" under "Selecting cycle
time".
Ventilation Mode
The devices change internal environment air (without recovering heat).
- Even number devices extract air from the environment.
- Odd number devices introduce air into the environment.
Speed adjustment (of devices) is automatic and ensures the correct balance of the Input/Output flow rates.
Further information on EVEN and ODD number devices is provided in the paragraph "Setting operating parameters" under
"Selecting the number of devices to be checked".
Air Extraction Mode
All connected devices extract air from the internal environment.
The air flow rates are all in Output toward the external environment.
⃝
A
⃝
B
⃝
C
⃝
A
⃝
B
⃝
C