- 45-
Function
code
Parameter name
Description
Default
Property
1
:
SVC(sensorless vector control)
Open loop vector without encoder
feedback and the feedback speed is
internally estimated and supports torque
control mode.
2
:
VC Vector control with sensor
Close loop vec tor and torque control
supporting encoder feedback in high
precision or torque control
application.The inverter must be
equipped with a PG card that matches
the encoder. For the relevant parameters
of the PG card, please refer to P10 group
P00.05
Running mode
0
:
Speed mode
1
:
Torque mode
If use with DI function,19:Switch between
torque and speed Control and 20: torque
control diabled. Actuall effective running
mode is related with DI status
0
★
P00.06
Source of the
Operation Command
0
:
keypad
1
:
terminal
2
:
communication
Command source: run
、
stop
、
forward
、
reverse
、
jog
、
fast brake stop.etc
If use with DI function, 12
:
Switching run
command to Keypad and 13
:
Switching
run command to Communication,Actuall
effective command source is related with
DI status
0
★
P00.07
Numeric frequency
setting
00.00Hz
~
maximum frequency
50.00Hz
☆
P00.08
Rotation direction
0
:
Forward
1
:
Reverse
It is only for keypad control to change
0
☆
Содержание IR610 Series