2.2 Specifications
Ranges Meters
7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 6km
Feet
23, 49, 98, 197, 394, 820, 1640, 3280, 6560,
9850, 19000
Range Selection
Manual range control
Accuracy
1% of selected range*
Resolution
Approx 1% of range
Sensitivity
Min 3 pixel return at 4km on 0.6mm Ø, PE, TP
Velocity Factor
Adjustable from 1% to 99% or Feet Meters /
Micro Second
Output Pulse
5 volts peak to peak. Into open circuit
Output Impedance
Selectable 25, 50, 75 & 100 ohms
Output Pulse Width
3 ns to 3 ms, Automatic with range
Scan Rate
2 scans / second or scan held
Memory Caoacity
50 Traces
Tone Generator
810 – 1100Hz
Battery Life
60 hours continuous scanning
Power Supply
6 volts 4 x 1.5 AA Alkaline cells
Power Down
Selectable 1, 2, 3 minutes or disabled
Back Lit Display
128 x 64 pixel
Voltage Protection
250 volts AC
Operating Temp
-10º / 50ºC
Storage Temp
-20º / 70ºC
Dimensions
165 x 90 x 37 (6.5 x 3.5 x 1.5 ins)
Weight
350 gms (12oz)
Safety
IEC 61010-1
EN 60950
EMC
BS/EN 61326-1
Water/Dust Proof
IP54
* Measurement accuracy of <+/- 1% assumes the instrument setting for
velocity of propergation (Vp) of the cable under test to be accurately set,
homogeneity of the Vp along the cable length, and accurate cursor
positioning.
7
Содержание RapidTrace 1200
Страница 1: ...RapidTrace 1200 User Guide Issue 1 0 ...
Страница 22: ......