communication
–
simple
–
flexible
–
unlimited
© Vonamic GmbH 2020
Subject to technical modifications
30
3.11
Time synchronization (NTP)
The V615 Industrial call station supports synchronization of the system time using an NTP (Network
Time Protocol) server. To do this, enter the IP address of the NTP server in the "
Time
Synchronization
"
segment in the "
NTP
Server
" field (e.g. 192.168.100.251). Then enter the time deviation, your time
zone, from the GMT (Greenwich Mean Time) in the "
GMT
" field (e.g. for G1). Confirm your
entry with "
Submit
".
Now the current date and time is displayed next to "
Date / Time
":
3.12
Amplifier lines
Another device in the VIPCOS series is the V1000 400W IP Amplifier. This device has 6, separately
controllable, speaker circuits or 3 loops. You can specify a selection of the speaker circuits for both
direct- and group -call connection to a V1000. All possible constellations can be made from one to all
lines. To do this, activate the respective checkboxes of the lines of the specific call connection to your
V1000.
If you do not configure any line information for the connection, the internal line selection of the V1000
is used. This can be set separately on the V1000 web interface. Confirm your entry with "
Submit
".