communication
–
simple
–
flexible
–
unlimited
© Vonamic GmbH 2020
Subject to technical modifications
11
2.5
Key Configuration
You can find the setting options for the keys in the "
Key
Configuration
" segment of the V615 Industrial
Call Station web interface. The device can have a total of 6 direct selection buttons. There are also
versions with 2, 4 and 6 buttons or with 4 buttons and keypad. The number of buttons displayed on
the web interface depends on the hardware version.
Call function:
Setting the connection type or the call function. (
Direct
call
,
group
call
,
telephone
call
,
Partyline
,
Hangup
)
Destination:
Enter the call destination. (1000 - 9999 neuronal)
Prio.:
Enter the call priority. (1-255)
Line selection:
Setting the playback lines of a V1000 IP 400W amplifier.
Callback:
As soon as this function has been set to an unassigned key, the device accepts
unknown SIP calls. The last incoming unknown number is stored in the
assigned key and can therefore be answered and called back.
(requires SIP server registration)
Megafon Key:
This function allows live announcements from the internal microphone to the
output of the 10W / 40W amplifier. enter the key number of an unassigned
key which you would like to use for the function.
(requires the connection of an external loudspeaker. Pay attention to feedback.)