6
GND
NC2
C2
NO2
I2
NC1
C1
NO1
I1
SC
GND
NC4
C4
NO4
I4
NC3
C3
NO3
I3
SC
4RL
120/240 VAC
50/60Hz
PS914
x 4RL
Access
Control
for Device 2
EL-LX Device 2
Auto Operator 2
EL
LX
(Optional)
EPT 10
Gray
White
Access
Control
for Device 1
EL-LX Device 1
Auto Operator 1
EL
LX
(Optional)
EPT 10
Gray
White
0-100 ft, use 14 gauge stranded wire
0-200 ft, use 12 gauge stranded wire
AO
- WIRING EXAMPLE - TWO SINGLE DOORS
Summary of Operation
For each door, access control input unlocks door.
Latch monitor (LX) triggers auto operator.
Single Door Board Confi guration
1. Position jumpers for dry contact for outputs 2 and 4
(see page 2).
2. Turn on switches 5 and 6 on SW1 (6 second time delay).
3. If LX is not used, turn on switch 1 on SW1.
AO
- WIRING EXAMPLE - DOUBLE DOORS
Summary of Operation
Access control input unlocks both doors.
Both latch monitors (LX) trigger auto operators.
Double Door Board Confi guration
1. Position jumpers for dry contact for outputs 2 and 4
(see page 2).
2. Turn on switches 4, 5, and 6 on SW1 (6 second
time delay).
3. If LX is not used, turn on switch 1
on SW1.
SW1
SW2
1 2 3 4 5 6 7 8
O N
O F F
1 2
SW1
1 2 3 4 5 6 7 8
O N
O F F
SW2
1 2
Access
Control
for Devices
1 & 2
EPT 10
EL-LX Device 1
EL-LX Device 2
Auto Operator
Auto Operator
White
Gray
EL
EL
EPT 10
GND
NC2
C2
NO2
I2
NC1
C1
NO1
I1
SC
GND
NC4
C4
NO4
I4
NC3
C3
NO3
I3
SC
4RL
120/240 VAC
50/60Hz
PS914
x 4RL
Gray
White
Second auto operator,
if needed
LX
(Optional)
LX
(Optional)
0-100 ft, use 14 gauge stranded wire
0-200 ft, use 12 gauge stranded wire
Note:
Fail secure output only
allowed if approved
by Authority Having
Jurisdiction
Refer to Wire Table
(page 7)