background image

5

See “

Preparation Chart

on page 3 for preparation

information

End cap

bracket flush

Mark and prepare 2

mounting holes

Level device

8

Install End Cap Bracket and End Cap      

B

C

Secure

end cap bracket

and end cap

10

11

9

Install Top Latch and Rod

Install Top Strike

Adjust Top Rod (Screw Rod Into or Out of Latch) Until 

Adjusted as Shown

D

Top 

latch

Top rod

(longer of 

the two)

#325 sex

bolts

(required)

If top rod is too long, see 

Cut Top Rod

” 

on page 7

If top rod is too short, see

Install Rod Extension

” 

on page 7

299/299F strike

E

Strike plate

(299 only)

Shim

to 

³⁄₁₆

"

as shown

³⁄₁₆

"

 260U strike

F

499F strike 

(for LBR devices)

See instruction 911009

With door 

open: 

With door 

closed: 

Release 

trigger

extended

Latch bolt 

deadlocked

(will not push in)

Latch bolt stays

retracted

 

6

Install Trim (if using) and Secure Device Center Case 

to Door 

Cente

r

case

A

Trim

(optional)

See “

Screw Chart

” 

on page 2 for screw

types and sizes

1

¹⁄₂

” Minimum clearance

(with end cap removed)

if device is too long for 

door, see “

Cut Device

” 

on back cover

7

Mark and Prepare 2 Holes for End Cap Bracket

Содержание 98/9927

Страница 1: ...re Surface Vertical Rod Exit Device CD98 9927 Cylinder Dogging Surface Vertical Rod Exit Device EL98 9927 Electric Latch Retraction Surface Vertical Rod Exit Device Specialtoolsneeded 5 64 hex wrench 10 24 tap Drill bits 25 1 8 1 4 5 16 13 32 Index Screw chart 2 Preparation chart 3 Device installation 4 6 Cut top rod 7 Install rod extension 7 Optional equipment 8 Cut device 8 Customer Service 1 87...

Страница 2: ...ombination 1 4 20X3 4 1 4 20X1 1 4 10 12x10 24x1 1 4 Combination 10 12x10 24x1 Combination 8 18x3 8 Threadcutting Surface mountor Sexbolts2 1 4 door Surfacemount wood 10 16x3 8 Threadcutting 1 3 4 door 2 1 4 door Metalframe Woodframe 8 32X1 4 Metalorwoodframe Variablefloorsurfaces Metal or wood door Centercasecover Sexbolts 1 3 4 door Endcap Latchcovers Packagedwithtrim 10 24X1 3 8 10 24 X 1 7 8 9...

Страница 3: ...32 Drill trim side 13 32 Drill thru Metal Wood Metal Wood Outside cylinder applications Mark with template and cut out Metal door cut device side Wood door cut thru Doorcut outs For trim applications with working lever thumbpiece or knob Mark with template and cut out cut device side only Bottomstrike 25 Drill 10 24Tap 1 8 Drill pilot 1 deep Metal Wood Latches 5 16 Drill device side 13 32 Drill tr...

Страница 4: ... locks and unlocks lever knob or thumb piece For the trims listed below REMOVE NL drive screw 996L 696TP 990TP 996K 697TP With the NL drive screw installed key retracts latch bolt DO NOT remove NL drive screw for the following applications NL EO DT trims and 98 99 2 double cylinder devices i e TP 2 L 2 and K 2 If the trim being installed is BE i e 996L BE the trim lock tumbler on the back of the d...

Страница 5: ...e Cut Top Rod on page 7 If top rod is too short see Install Rod Extension on page 7 299 299F strike E Strike plate 299 only Shim to as shown 260U strike F 499F strike for LBR devices See instruction 911009 With door open With door closed Release trigger extended Latch bolt deadlocked will not push in Latch bolt stays retracted 6 Install Trim if using and Secure Device Center Case to Door Center ca...

Страница 6: ...open toplatchretracted D Bottom rod Bottom latch 325 sexbolts required 13 Adjust Bottom Rod with Door Open Top Latch Retracted Open and close door a few times and check for deadlatching when door is closed Readjust rods if needed With door open With door closed Latch bolt should clear floor and not bind on strike Latch bolt should be deadlocked will not push in Install at midpoint of each rod See ...

Страница 7: ...ru 5 Connect top rod and rod extension Top rod Rodextension Actual door opening height 1 Measuredooropeningtodetermine amounttocutoffrodextension INSTALLRODEXTENSION 84 Amount to cut off Actual door opening height Standarddoorheights With no extension 7 84 With 1 extension 8 96 With 3 extension 10 120 Rods are factory sized for 7 84 door Measure actual door opening height and subtract that number ...

Страница 8: ...inder cam CDfunctionconversion Figure 1 Figure 2 Std mortise cylinder Cylinder collar Dogging plate cover Offset toward pushbar Cylinder locatingwasher Cylinder lock nut Mechanism case Turn cylinder key clockwise approx 1 8 turn for standard dogging Doggingprocedure Depresspushbar CD CYLINDER DOGGING CUTDEVICE 5 16 1 1 2 minimumclearance with endcap removed Devicealigned with mounting holes Tape C...