135
Intercooler
Pressure-testing
For single-circuit system
Special tools:
(999) 6662 Pressure gauge
6815 Connection washer
6816 Sealing washer
For two-circuit system
Special tool:
(999) 6662 Pressure gauge
1.
Connect the pressure gauge to the compressed-air
system. Set pressure at 50 kPa (0.5 kp/cm
2
).
2.
Fit the cover washer.
6816
3.
Connect the pressure gauge to the nipple and test
the pressure. It must not drop during one minute. If
it does, replace the intercooler!
6662
6815
4.
Increase pressure to 150 kPa (1.5 kp/cm
2
). Pres-
sure must not drop during one minute. If it does,
replace the intercooler!