9. Turbopressure sensor. To be able to compare the
measured voltage value for max. turbo pressure
with the value given in the specifications for the
engine in question, it is necessary to correct the
value with a view to the fact that the reference
voltage can vary. The new value we call Unorm.
Unorm =
measured voltage
value, control rod
X
travel
If the measuring is done at a temperature other
than +20
°
C, then the value must also be corrected
in order to be able to compare it with the voltage
value specified in the specifications. The estimat-
ed Unorm value is corrected as per the following
graph.
5
measured
reference
voltage
Example
The voltage for the turbo pressure Unorm is estimated
at 3.7 V at an ambient temperature of 0
°
C.
–
Go in on the vertical axis in the diagram to 3.7 V.
–
Follow the horizontal axis to the right until it inter-
sects the vertical line for 0
°
C ambient temperature.
–
The corrected voltage is read-off on the respective
curve in the diagram. In our example 3.5 V, which
corresponds to the voltage at 20
°
C.
10. An oscilloscope is required for a complete check
on the injection pump speed sensor. Max. differ-
ence in positive amplitude 1.4 V. Positive ampli-
tude should lie between 10–30 V at 1200 r/min en-
gine speed (injection pump revs 600 r/min).
At low idle (550 r/min), positive amplitude should
lie between 2.3–11.6 V (50–60 Hz). Average A.C.
voltage 2.2–2.4 V (average reading voltmeter).
Содержание DH10A 245
Страница 1: ...Service Manual Buses Section 2 20 27 Engine DH10A 245 285 345 350 360 TP 16031 1 ...
Страница 31: ...30 Adjust in the supports on the lift unit as shown in the pictures below ...
Страница 59: ...58 Cylinder block crank mechanism ...
Страница 162: ...Volvo Bus Corporation TP 16031 1 English 2500 06 97 Printed in Sweden by Novum Grafiska AB 97 24296 Göteborg Sweden ...