Group 87 Climate Control, Fault Codes
Specifications
Termi-
nal
Signal type
Measurement
points
Nominal value
Other
BSA9
Power supply, ignition key in
driving position
BSA9 - BSA15
V
≈
B+
15
BSA10
BSA11
Supply voltage
BSA11 - BSA15
V
≈
B+
30
BSA12
Magnetic clutch, air
conditioning (A/C) compressor
BSA12 - BSA15
V
≈
B+
Engine running
BSA13
BSA14
Fan, sensor cab temperature
BSA14 - BSA15
V
≈
B+
BSA15
Ground connection
BSA15 - Ground
V
≈
0 V DC
31
BSB1
BSB2
Engine fan control
BSB2 - BSA15
V
≈
B+
Engine cooling fan
active
BSB3
Ground terminal sensor
BSB3 - Ground
V
≈
0 V DC
BSB4
SAE J1708 Data link B
BSB4 - Ground
V
≈
0 - 5 V DC
BSB5
SAE J1708 Data link A
BSB5 - Ground
V
≈
0 - 5V DC
BSB6
Sensor sytem pressure, signal
volts
BSB6 - Ground
V
≈
0.5 - 4.5 V DC
BSB7
Stepper motor phase 1 (low)
BSB8
Stepper motor phase 2 (low)
BSB9
Stepper motor phase 3 (low)
BSB10
Stepper motor phase 4 (low)
BSB11
Stepper motor, by pass, signal
voltage
BSB11 - BSB7 - 10
V
≈
< 10 V
Stepper motor
active (Rotate
knob)
BSB12
Stepper Motor, Air distribution,
signal voltage
BSB12 - BSB7 - 10
V
≈
< 10 V
Stepper motor
active (Rotate
knob)
BSB13
Stepper Motor, recirculation,
signal voltage
BSB13 - BSB7 - 10
V
≈
< 10 V
Stepper motor
active (Rotate
knob)
BSB14
BSB15
Engine coolant valve, voltage
supply
BSB15 - BSA15
V
≈
B+
Select Max heat
position, Electronic
climate control
(ECC) only
BSB16
BSB17
BSB18
Sensor system pressure,
voltage supply (5v)
BSB18 - BSA15
V
≈
4.5 - 5.5V
BSB19
Temperature sensor evaporator,
signal voltage
BSB19 - BSA15
V
≈
0 - 5 V
BSB20
Temperature sensor, heat
exchanger, signal voltage
BSB20 - BSA15
V
≈
0 - 5 V
BSB21
Not connected
4