26
Emergency stop*
TAMD162C**, TAMD163A
If the engine must be stopped immediately the emer-
gency stop can be used.
The emergency stop is engaged by pressing the sepa-
rate “STOP”-button at the control position, in the engine
room or at any other position.
When the stop solenoid is activated, the injection
pump’s control rod is moved into the zero delivery posi-
tion and the engine stops as the flow of fuel is cut off.
* Note. Applies to classifiable engines.
** Classifiable engines are fitted with a fuel shut-off valve for
normal stop).
Emergency start*
TAMD162C, TAMD163A
There is an emergency start button at the starter motor.
The emergency start button functions independent of
the key switch being on or off. The button has no start
interlock function and should therefore never be
pressed while the engine is running.
If the button is used for starting, first ensure
that no damage can be caused.
* Note. Applies to classifiable engines.
1
2
Emergency stop/-start (TAMD162C, TAMD163A)
1.
Emergency stop (stop solenoid)
2.
Emergency start button