Emptying the water separator
WARNING!
Hot fuel can cause burns.
1 Open the drain tap (
1
) and empty the water and
sediments from the water separator (
2
) by pumping
with the hand pump (
3
) until clean fuel runs out.
Fuel pre-filter
Volvo Penta fuel pre-filters are supplied in single and
double models.
Checks
The double filter is fitted with a pressure gauge
1
that
indicates when it is time to replace the filter cartridges.
The filter cartridges must be replaced according to
maintenance schedule recommendations, or earlier if
the pressure gauge shows a pressure drop of 6–10 in.
Hg at idle or 16–20 in. Hg at full rpm/engine load.
WARNING!
Working with or approaching a running engine is a
safety risk. Watch out for rotating components and hot
surfaces.
Draining
Place a vessel under the filter. Empty the water and
sediment through the plugs (
2
).
3
1
2
P0010382
Maintenance
92
47705796 05-2014 © AB VOLVO PENTA
Содержание IPS
Страница 1: ...OPERATOR S MANUAL Volvo Penta IPS ...
Страница 138: ......
Страница 139: ... 2014 AB VOLVO PENTA Volvo reserves the right to make changes Printed on environmentally friendly paper ...
Страница 140: ...47705796 English 05 2014 ...