Drive
The drive is protected against galvanic corrosion by
several layers of paint, sacrificial anodes and ground
braids. The ground braids maintain a connection
between the different components of the drive. A bro-
ken connection can result in the rapid corrosion of an
individual component even though the protection is
otherwise effective. Check ground braids every year.
Faulty electrical installation can also cause the break
down of the galvanic protection. Damage due to elec-
trolytic corrosion occurs rapidly and is often extensive.
For further information see the chapter
.
Always repair damage to paintwork immediately.
Improperly applied paint or the wrong type of paint on
the keel can put the corrosion protection system out of
action. For further information on painting see section
.
Transmission lubricant, checking
and topping up
IMPORTANT!
Never over-fill the drive. The oil level must always be
within the recommended range.
1 Screw the oil dipstick all the way down and then
remove it.
2 Check the oil level on the dipstick. The oil must be
on the flat dipstick area
If the oil level is low, fill a little at a time through the
oil dipstick opening until the right level is reached.
For oil grade and quantity refer to
If oil level is too high, empty the drive until the cor-
rect level is achieved; refer to
.
3 Check O-ring on dipstick for wear; replace if
needed.
The oil must have a golden brown nuance. If the oil is
gray, water has entered the stern drive. In this case let
a Volvo Penta workshop carry out checks on the stern
drive.
MAX
MIN
P0002493
Maintenance
106
47705992 05-2015 © AB VOLVO PENTA
Содержание D3
Страница 1: ...OPERATOR S MANUAL D3 ...
Страница 140: ...Trim Controls 33 Trim Instruments 34 Trim Ranges 32 V Vacuum Valve Cleaning 97 Viscosity 131 W Water Quality 132 138 ...
Страница 141: ... 2015 AB VOLVO PENTA Volvo reserves the right to make changes Printed on environmentally friendly paper ...