Installation and operation
The remote on-off/ ignition control terminal at the back of the unit are shorted as
default setting for continuous operation.
See section of instruction for remote on-off and ignition control application in the
appendix A.
DC-DC CHARGER INSTALLATION:
1. Check all the DIP SWITCHES are at down position
2. Push up the single DIP SWITCH that matches your battery type
3. DIP 1 = AGM/ GEL; DIP 2 = WET; DIP 3 = CALCIUM-CALCIUM
4. Only one DIP switch is allowed to be in up position
5. Double check for correct polarity on the input and output before
connections are made.
Any wrong polarity on the input or output connection will damage unit.
6. LED A in green color when unit is working normally.
7. LED C shows the charging status:
Flashing Green = Boost Charging (Bulk/ Absorption)
Solid Green = Float Charging with less than 10A & less than 13.8V