81
22.4 Digital camera
Field of view (FOV)
.......................
59°
Resolution .....................................
2 MP
22.5 Temperature measurement
Temperature range .......................
-20 to +150 °C (-4 to +302 °F)
0 to +550 °C (+32 to +1022 °F)
Accuracy .......................................
±2 °C (±3.6°F) or ±2 % of reading
(Environment tempe10 to +35 °C;
Object temperature >0 °C)
Emissivity ...................................... 0.01 - 1.00
22.6 Temperature measurement analysis
Spot .............................................. Centre spot
Three manual spots
Automatic hot/cold detection ........ Auto hot or cold markers
Area analyses ............................... Three areas
Line analyses ................................ Two lines
Measurement corrections
.............
Emissivity, reflected temperature, ambient
temperature, atmospheric humidity, infrared
compensation, distance compensation
22.7 Image presentation
Display .......................................... LCD
Display resolution .........................
640 x 480 px
Display size ..................................
89 mm (3.5”)
Image modes ................................ IR image, visual image, picture in picture, auto
fusion
Colour palette ............................... Iron, rainbow, white hot, black hot, brown hot,
blue-red, hot-cold, feather, above alarm, below
alarm, zone alarm, vision zone