VPS-DOS-TR-04-E / Rev 01
6-January-2022
Volta Power Systems
Page 22 of 34
Charging via Generator
Similarly to charging via shore power, the Flex Pack can charge via connection to
a generator� An on-board RV generator or a traditional generator can charge the
Flex Pack if the generator meets the inverter’s requirements, such as AC input
range and frequency�
When plugged into a generator, the inverter samples incoming power for a few
seconds to ensure uniformity requirements are met� If incoming power meets
the requirements, the Volta System turns on and begins charging the Flex Pack�
If the Flex Pack does not charge from a generator, this condition may be due to
unclean or unstable power from the generator�
The Volta System can be integrated with a generator using an auto-start and
auto-shutoff feature, creating a hybridized charging system that increases
efficiency for the Volta System and the generator�
Recovery from Zero State-of-Charge
The Battery Management System shuts down the Volta System if the Flex Pack
reaches a very low voltage limit or 0% State-of-Charge (SOC). When the Volta
System reaches 0% SOC, the pushbutton LED flashes yellow, the SOC is red, and
the system shuts down� Do not attempt to turn on the system until a charge
source is connected� Perform one of the following recovery procedures (follow
page).
Recovery from Zero SOC - Shore Power
1.
Turn off the Volta System, if not off already�
2.
Connect to shore power�
3.
Ensure the appropriate charge rate is selected�
Refer to Inverter
Screen on page 19 for details on changing the charge rate
selection.
4. Charge the system to at least 20% SOC before returning to normal
system operation and use� Fully charge the system as soon as pos-
sible�
Recovery from Zero SOC - Alternator
1.
Turn off the Volta System, if not off already�
2.
Start the vehicle� Immediately raise and hold the engine RPMs over
1500 for at least five minutes.
3. Drive the vehicle, maintaining at least 1500 RPM, to charge the
system until the SOC indicates at least 20% SOC before returning to
normal system operation and use�
4.
Fully charge the system as soon as possible�
Perform one of the recovery procedures as soon as possible� Failure to recover
from a low voltage shutdown will result in further Flex Pack discharge, which
may require service from a Volta technician�