4. OPERATION

4.1 Standby

With the power supply connected the control box is initially in standby mode and the green ‘Power’ LED on the control 
box flashes slowly but there is no display and the pump is not functioning.  

4.2 On

Switch on by pressing the Power key (              ).  The green   ‘Power’ LED on the control box illuminates continuously, all 
keys are active and the following information appears on the display in sequence: ECOSYLER; version number; estimated 
crop harvest rate (t/h).

Note: If you have not wired the control box to a table sensor you must reconfigure your control box to show this 
as the control box is supplied assuming a table sensor is attached (see sections 7 and 7.5).

Harvesters with a table sensor:

  The pump will start automatically when the table is lowered and the harvester begins 

harvesting the crop. It will stop when the table is lifted. 

Harvesters without a table sensor: 

The pump is turned on and off manually using the              and              keys 

respectively. 

When the pump is operating the green ‘Pumping’ LED on the control box flashes. 

All harvesters:

Pressing the               key switches the system back to STANDBY.

Pressing the                 key once (hold down 1 sec) switches to Cleaning mode ‘forward ‘or twice (2 rapid clicks) to Cleaning 
mode ‘reverse’.

Pressing the                 key takes you into the menu where you can reset the counter and change various applicator 
parameters (see section 7). 

4.2.1 Cleaning mode 

Cleaning mode ‘forward’ is selected by holding the                 key down for 1 second. The display shows ‘Pump 

>>>

’ and the 

pump operates at full speed, allowing the tubing to be rapidly filled with inoculant, or water if it is being washed out.

Cleaning mode ‘reverse’ is selected by a rapid double click of the                key. The  display  shows ‘Pump 

<<<

’ and the 

pump operates at full speed in reverse, to run any inoculant in the tubes back into the tank.

The cleaning mode can only be selected when the control box is switched on and the pump is not already operating.              
If a table sensor is connected, the table should be raised; if there is no sensor, switch off the pump using the              key.          
The cleaning mode finishes after one minute automatically but can be interrupted by pressing the               key once. It 
will also stop when the pump is switched on.

 

TANK FITTINGS

CONTROL BOX

PUMP

P

-3-

Low Level

Indicator

Tube

Holder

Input

To Control

Box

To Low

Level

Indicator

Output

Pump

tubing

Centre

hub

Electrical

connection

to pump

3 way valve

Tank

Drain

Tubing

connector

Power On/Off

and LED

Not in use

Pumping

Cleaning On/Off

Alert LED

Menu keys

Manual Pump

On/Off keys

Содержание Ecosyl ECOSYLER 08

Страница 1: ...ting mode 4 5 Counter 4 6 Alerts 4 6 1 Low Level 4 6 2 Pump 4 7 Control Box Menu 4 7 1 View the counter reading Counter tonnes or litres 4 7 2 Reset the counter ctr clr CTR 0 6 7 3 Application rate Do...

Страница 2: ...et supplied 2 3 Nozzle The nozzle should be placed in the lower side of the chute approximately midway along its length eg fit into the centre of a convenient cleaning flap Drill a 14mm diameter hole...

Страница 3: ...ches to Cleaning mode forward or twice 2 rapid clicks to Cleaning mode reverse Pressing the key takes you into the menu where you can reset the counter and change various applicator parameters see sec...

Страница 4: ...both of which cause the Alert LED on the control box to flash and an audible warning which can be cancelled by pressing the key The display will return to normal but the red LED continues to flash un...

Страница 5: ...NB Before returning to harvest mode you must confirm all 3 digits even if only one changed t h or l h rate of harvest or additive use Counter accesses the counter t or l total tonnes harvested or lit...

Страница 6: ...e control box 8 Collect at least 500ml 4 minutes then stop the pump by pressing the key 9 View the counter reading in litres 10 Divide the amount of inoculant collected by the counter reading the coun...

Страница 7: ...becoming constricted due to prolonged compression at the contact points see below Alternatively once a week remove the clear pump cover and red disc and manually turn the central hub to a new positio...

Страница 8: ...for constrictions or breaks in the tubing and blockages including in the pump Control box power light on but nothing showing on LCD screen Try switching the power source off and on again ie switch ha...

Страница 9: ...l Box 7 Tank 8 Pump Housing Cover 9 Pump Housing 10 Pump 11 6mm Hose Tail 12 Quick Connector A 13 Quick Connector B 14 Nozzle Item No Description 15 Quick Connector A 16 Quick Connector B 17 10mm Hose...

Отзывы: