10. WARRANTY
Provided installation, operation and maintenance is carried out according to the instructions provided with the
applicator, a warranty of 1 year from the date of delivery applies. This covers faulty manufacture only; it does not
cover wear and tear through normal use and is invalidated if any mechanical or chemical damage has occurred to the
parts through misuse or if attempts to repair the unit have resulted in damage. In the case of faulty manufacture,
claims are limited to the repair of the unit and its return to the customer.
11. TECHNICAL DATA
Supply voltage:
12V DC (10.6V DC to 16.4V DC)
Output signal for Ecosyler pump:
PWM approx. 80 Hz
Working ambient air temperature:
5 - 50°C
Dimensions tank assembly (WxDxH): 410 x 290 x 590 mm
12. REPAIRS & SPARES
Selmech Supplies
19 Norton Enterprise Park, Whittle Road, Churchfield Industrial Estate, Salisbury, Wilts, SP2 7YS.
Tel: 01722 413440 Fax: 01722 413466 Email: [email protected]
9. TROUBLESHOOTING
-8-
Problem
Solution
Check connections and for blockages.
Check control box configuration (Cfg Dev) correctly set for +/- table
sensor (1
st
digit). If table sensor present, table must be down for pump
to work.
Check the tap under the tank is open.
Check for constrictions or breaks in the tubing and blockages (including
in the pump).
Control box power light on but nothing showing on LCD
screen
Try switching the power source off and on again, ie switch harvester
ignition off then on.
Control box not working
Is there power to the control box (green LED)? If not, check connections
and fuse (fuse holder on end of control box).
It must be switched ‘ON’ (green LED on continuously).
Try switching it off completely and back on again.
If table sensor present, table must be up.
If no sensor make sure pump is off.
When fill tank and turn on control box, the tank empty alert
comes on
The low level sensor has become stuck as a result of the system not
being flushed with clean water after use. Drain the inoculant from the
tank and wash through with a strong jet of water. If that does not work,
unscrew the LLI and flush through from the other side. This should free
the cylinder that rides up and down the spindle inside the low level
Counter not working properly
Was the reset confirmed before returning to harvesting mode? Reset the
counter to zero again and make sure the tick button is pressed to
confirm.
Pump error alert on control box
Pump working but no inoculant flowing
Power to the control box but buttons not responding
Cleaning mode not working
For more information on ‘Eco’ Applicators contact:
Freephone
| 0800 9198080
Visit
| www.ecosyl.com