Supplied By www.heating spares.co Tel. 0161 620 6677
13
4.8.3
CONNECTING THE MAINS (230V) INPUT
(see fig. 15)
Remove the electrical input board cover as
described in 4.8.2. Pass the cable through the
cable anchorage (see fig. 6). Connect the supply
cable wires (earth, live, & neutral) to their
corresponding terminals on the electrical input
board. Ensure that the EARTH wire is left slightly
longer than the others, this will prevent strain on
the Earth wire should the cable become taut.
Do not remove the 24V link wire (between
terminals 2 & 3 on plug M4) unless additional
external controls are to be fitted (see section 8).
Re-fit the electrical input board cover.
The securing screw on the cable anchorage
should now be tightened. This must be done
before the control fascia is re-fitted in the upright
position. The appliance casing and screws can
now be re-fitted.
Fig. 15