Product Introduction
© BTG 2020
User Manual CPM PI2066en Rev.C
5
HCM-8010
Hart communication module using HART
®
protocol.
Equipped with slot for SD memory card.
Analog output (AO1- AO5)
4 - 20 mA. Galvanic isolated. Current limited to min. 3.9 and max. 20.5 mA.
Loop load signal: Voltage supply/load 24 V DC
Active output
Superimposed signal over 4 - 20 mA current loop according to standard HART
®
protocol.
Analog input (AI1 - AI4)
4 - 20 mA 250 Ω input resistance
Digital input (DI1 - DI4)
Galvanic isolated
High-ohmic = logical 0
+24 V ≥ 12 mA = logical 1
Digital output (DO1 - DO2)
Galvanic isolated
Maximum 120 mA
Maximum 30 V DC
Solenoid valve (SV1 - SV5)
Open drain output for solenoids
Maximum 500 mA
Maximum 30 V DC
FCM-80x0
Fieldbus communication module programmed for PROFIBUS.
Equipped with slot for SD memory card.
Output / Input signal
PROFIBUS (PA)
CCM-8200
Network Interfaces:
Wired Network Connectivity
Ethernet, 10/100 Mbit - RJ45.
Ethernet interface supporting up to 100baseTx.
IEC 11801:2002 CatV compliant M12 type D socket.
The interface supports Auto MDI-X (crossover).
Wireless Network Connectivity
Wi-Fi, Dual-band 802.11 a/b/g/n/ac 1x1
CPM User Interface
Illuminated display. Key pad for adjustment of instrument settings.
Содержание BTG CPM-1300
Страница 1: ...User Manual CPM Communication Platform...
Страница 18: ...Product Introduction 14 User Manual CPM PI2066en Rev C BTG 2020...
Страница 34: ...Service Instructions 30 User Manual CPM SI2066en Rev A BTG 2020...
Страница 50: ...Parts List 46 User Manual CPM PL2066en Rev A BTG 2020...
Страница 60: ...Appendix 56 User Manual CPM AX2066en Rev C BTG 2020...
Страница 61: ......
Страница 62: ...BTG Instruments AB P O Box 602 SE 661 29 S ffle Sweden Phone 46 533 426 00 www btg com...