Appendix
© BTG 2020
User Manual CPM AX2066en Rev. C
51
Connection Block
SPK-5500 Single Channel
SPK-5500 Dual Channel
TCR-25x2
P1
DI3
Digital In 3
Remote stop
Remote stop
Sample Input
DO
Digital Out 1
Floating DC switch max
30 V, 100 mA
Alarm Output
Alarm Output
Alarm Output
P2
DI1
Digital In 1
Calibration set Input A
Calibration set Input
Calibration set Input A
DI2
Digital In 2
Calibration set Input B
Not used
Calibration set Input B
P3
AO
Analog Out 1
Kappa LRV - URV
output value
4 - 20 mA
Channel 1 LRV - URV
output value
4 - 20 mA
Total consistency
(Channel 1) output value
4 - 20 mA
AI
Analog In1
Not used
Not used
Not used
P4
AO2
Analog Out 2
RMS 0-0.0015 V
output value
4 - 20 mA
Channel 2 LRV - URV
output value
4 - 20 mA
Ash consistency
(Channel 2) output value
4 - 20 mA
AO3
Analog Out 3
CwZ 0-1.65 V
output value
4 - 20 mA
aCwZ 0-1.65 V
output value
4 - 20 mA
Not used
P5
AO4
Analog Out 4
CwT 0-0.165 V
output value
4 - 20 mA
aCwT 0-0.165 V
output value
4 - 20 mA
Not used
AO5
Analog Out 5
Mean Kappa
(a)
LRV - URV
output value
4 - 20 mA
Channel 1
(a)
mean value or RMS
output value
4 - 20 mA
P6
AI2
Analog In 2
Internally pre-wired
(b)
Internally pre-wired
(b)
Not used
AI3
Analog In 3
AI4
Analog In 4
P7
DI4
Digital In 4
Sample Input
Sample Input
Not used
DO2
Digital Out 2
Floating DC switch max
30 V, 100 mA
Data Ready or Clean Pump
Data Ready or Clean Pump
P8
SV4
Sol. valve 4
Internally pre-wired
(b)
Internally pre-wired
(b)
Not used
SV5
Sol. valve 5
P9
SV1
Sol. valve 1
Internally pre-wired
(b)
Internally pre-wired
(b)
Not used
SV2
Sol. valve 2
SV3
Sol. valve 3
(a) Average since last start. Normally only used for batch applications
(b) For more information about internally pre-wired connections, see the installation drawing for the transmitter
Содержание BTG CPM-1300
Страница 1: ...User Manual CPM Communication Platform...
Страница 18: ...Product Introduction 14 User Manual CPM PI2066en Rev C BTG 2020...
Страница 34: ...Service Instructions 30 User Manual CPM SI2066en Rev A BTG 2020...
Страница 50: ...Parts List 46 User Manual CPM PL2066en Rev A BTG 2020...
Страница 60: ...Appendix 56 User Manual CPM AX2066en Rev C BTG 2020...
Страница 61: ......
Страница 62: ...BTG Instruments AB P O Box 602 SE 661 29 S ffle Sweden Phone 46 533 426 00 www btg com...