Appendix
54
User Manual CPM AX2066en Rev. C
© BTG 2020
6.4 FCM-8010 Connections
Connection Block
RET-55xx
RT-5500
SPC-5500
SPM-5500
SPK-5500
Single Channel
SPK-5500
Dual Channel
P1
DO
Digital Out 1
Alarm Output
Alarm Output
Alarm Output
Alarm Output
Alarm Output
Alarm Output
DI3
Digital In 3
Interlock
Sample Input
Interlock
Interlock
Remote stop
Remote stop
P2
FF / PROFIBUS PA
See separate table below for data between Profibus and Transmitter
P4
AO2
Analog Out 2
Ash Consistency
(Channel 2)
output value
4-20 mA
(RET-55x3 only)
Conductivity
(Channel 2)
output value
4 - 20 mA
White water
charge
(Channel 2)
output value
4 - 20 mA
Configurable
(Channel 2)
output value
4 - 20 mA
RMS 0-0.0015 V
output value
4 - 20 mA
Channel 2
LRV-URV
output value
4 - 20 mA
AO3
Analog Out 3
Internally
pre-wired
(a)
(a) For more information about internally pre-wired connections, see the installation drawing for the transmitter
Media temp.
(Channel 3)
output value
4 - 20 mA
Start streaming
potential for
filtrate (Channel
1)
Configurable
(Channel 3)
output value
4 - 20 mA
CwZ 0-1.65 V
output value
4 - 20 mA
aCwZ 0-1.65 V
output value
4 - 20 mA
P5
AO4
Analog Out 4
Not used
Not used
Start streaming
potential for
white water
(Channel 2)
Internally pre-
wired
(a)
CwT 0-0.165 V
output value
4 - 20 mA
aCwT 0-0.165 V
output value
4 - 20 mA
AO5
Analog Out 5
Not used
Mean Kappa
output value
4 - 20 mA
Ch1 mean value
or RMS
output value
4 - 20 mA
P6
AI2
Analog In 2
Not used
Analog input
signals from
external
equipment
4 - 20 mA
Not used
Internally pre-
wired
(a)
Internally
pre-wired
(a)
Internally
pre-wired
(a)
AI3
Analog In 3
Not used
AI4
Analog In 4
Not used
P7
DI4
Not used
Internally
pre-wired
(a)
Not used
Not used
Internally pre-
wired
(a)
Sample Input
Sample Input
DO2
Digital Out 2
Data ready
Channel 1
Not used
Data Ready or
Chem Clean
Pump
Data Ready or
Chem Clean
Pump
P8
SV4
Sol. valve 4
Internally
pre-wired
(a)
Not used
Not used
Internally pre-
wired
(a)
Internally pre-
wired
(a)
Internally pre-
wired
(a)
SV5
Sol. valve 5
Not used
P9
SV1
Sol. valve 1
Internally
pre-wired
(a)
Not used
Data ready
Channel 2
Internally pre-
wired
(a)
Internally pre-
wired
(a)
Internally
pre-wired
(a)
SV2
Sol. valve 2
Not used
SV3
Sol. valve 3
Содержание BTG CPM-1300
Страница 1: ...User Manual CPM Communication Platform...
Страница 18: ...Product Introduction 14 User Manual CPM PI2066en Rev C BTG 2020...
Страница 34: ...Service Instructions 30 User Manual CPM SI2066en Rev A BTG 2020...
Страница 50: ...Parts List 46 User Manual CPM PL2066en Rev A BTG 2020...
Страница 60: ...Appendix 56 User Manual CPM AX2066en Rev C BTG 2020...
Страница 61: ......
Страница 62: ...BTG Instruments AB P O Box 602 SE 661 29 S ffle Sweden Phone 46 533 426 00 www btg com...