15
©
VOI
SPEED
L
TD
.
VOI
SPEED
V-6017
NOTE: we strongly suggest assigning a static IP address to the V-6017
Here you can also define other important settings:
•
Web Server Port:
is the port used by the adapter to display the web interface. You will
need to specify the port number only if this is different from 80:
http://_IPaddress_:_Port_/
in which ‘
Port’
is the port value and ‘
IPaddress’
is the adapter’s IP address.
•
Reply to ICMP:
determines whether the adapter must reply to ICMP queries (such as
the
‘ping’
command) or not.
Call
This section includes settings relating to the PSTN analogue line.
The FXO allows
to connect
immediately
With this option you can determine whether a call needs to be
transferred to the PBX or alternatively re-directed to the emergency
phone. In the latter case you can also specify how long the phone
needs to ring before the call is transferred to the PBX.
Forward to VoIP
Here you can enter the PBX number you want the call to be
transferred to. Any PBX’s extension number can be specified (i.e.
user, hunt group, IVR node, etc.).
PSTN Access
Key
Here you can enter a sequence of numbers and simbols that, once
entered at the emergency phone, will give it access to the PSTN line
(FXO line).