background image

©

 

VOI

SPEED 

L

TD

.

 

VOI

SPEED 

V-6017 

   

3.1 - 

 

Product Disposal 

 
 
Our  products  are  compliant  with  the  European  Directives 
2002/95/CE, 2002/96/CE and 2003/108/CE regarding the limitation 
of use of lead, mercury, cadmium, chromium (VI) as well as some 
flame  retardants  and  hazardous  material  within  electric  and 
electronic equipment and disposal. 

 
 
The  sign  above  representing  a  crossed  waste  bin  indicates  that  the  product,  once  no 
longer  utilised,  must  be  disposed  of  by  separating  it  from  any  normal  waste.  The  user 
must ensure that the product, once reached its end-life, is given to qualified organisations 
responsible for the collection of electronic and electrical waste. The user may otherwise 
choose to return the equipment to the manufacturer when purchasing a new equivalent 
device. In this case the product returned must correspond to the one being purchased. 
Suitable disposal of the equipment in accordance with relevant recycling guidelines helps 
the  environment  and  fosters  sustainable  development.  Unlawful  disposal  of  this 
equipment is an offence and may lead to prosecution in accordance with the Country’s 
laws in which the disposal takes place. 
 

Correct disposal benefits us and the environment. 

3.2 - 

 

Product Warranty 

 
The Manufacturer (Harpax Srl.) warrants its products to be free from defects in material 
and workmanship during the warranty period. The product is covered by warranty only if it 
is used in compliance with the guidelines contained in this manual. This warranty will be 
invalidated in case of manumission, wrong use of the product or accidental damage. This 
product is compliant with CE regulations. 
 
The warranty period starts from the date the product has been purchased (stated on the 
invoice) and will last for twelve (12) months thereafter. If a product proves to be defective 
in material or workmanship during the warranty period, The Manufacturer will, at its sole 
discretion, repair or replace the product with a similar one (new or re-conditioned). The 
replacement unit will be covered by a new warranty period that will last the remaining time 
on  the  customer's  original  limited  warranty.  The  old  equipment  substituted  will 
automatically become property of Harpax Srl. 
 
In order to have access to the warranty the user must fill out the online form that can be 
found  on 

www.prontopbx.com

  or 

www.voispeedltd.com

  (please  also  contact  the 

customer support department on 01727 848186). The user must provide a valid invoice to 
claim warranty on the product. 

Содержание V-6017

Страница 1: ...1 VOISPEED V 6017 ANALOGUE ADAPTER VOISPEED V 6017 User Manual...

Страница 2: ...ohibited without prior written consent of the publisher Such consent will only be granted in those instances when the source of the document is clearly stated Revision 1 0 Released on 08 10 2007 Decla...

Страница 3: ...3 Main functionalities 8 4 4 List of components in the package 8 5 Getting started 8 5 1 Mounting Instructions 8 5 2 Requirements 9 5 3 Installation 9 5 4 Emergency Line 10 6 Manual Setting 10 7 Web I...

Страница 4: ...ct the device to other devices please read the user guide of the new equipment first Do not connect the device to any non compatible products Avoid prolonged exposure to direct sunlight Do not place t...

Страница 5: ...takes place Correct disposal benefits us and the environment 3 2 Product Warranty The Manufacturer Harpax Srl warrants its products to be free from defects in material and workmanship during the warr...

Страница 6: ...y where the product is utilised Damages resulting from misuse negligence unauthorized product modification repair or attempted repair by anyone not authorized by The Manufacturer including the user or...

Страница 7: ...pply outages The V 6017 is also provided of an additional switch port that is particularly useful in case of multiple V 6017 installations or it can be used to connect another network device to the LA...

Страница 8: ...NS ARP and ICMP Standard encryption and authentication DIGEST using MD5 The system can send event logs to an external Syslog server Firmware upgrade through TFTP FTP or HTTP Date time synchronisation...

Страница 9: ...igure the adpater from web As default the adapter will query the DHCP server for a valid IP address as soon as it is connected to the LAN In order to find this address you need to use the vocal menu s...

Страница 10: ...g correctly 6 Manual Setting It is possible to setup the V 6017 adapter using an analogue telephone connected to the FXS port You will need to enter at the phone in order to access the configuration m...

Страница 11: ...g In case you entered the adapter s MAC address the default setting will be applied after reset Note the MAC address is a 12 digit number that can be found in the label underneath the adapter You will...

Страница 12: ...ddress The default password to access the web interface is voip We reccommend changing this password at the first access 7 1 Current Status By pressing on current status the system will show a summary...

Страница 13: ...ting can be done automatically by the DHCP server or entered manually Browising the vocal menu section 6 Manual Setting you can determine the adapter s IP address By selecting Dynamically Assigned IP...

Страница 14: ...IP address to assign to the adapter This needs to be a unique number not assigned to any other devices on the network Subnet Mask Address mask identifying the Sub network it is usually 255 255 255 0...

Страница 15: ...and or not Call This section includes settings relating to the PSTN analogue line The FXO allows to connect immediately With this option you can determine whether a call needs to be transferred to the...

Страница 16: ...ing mode and the server s name and IP address Firmware Server By setting the auto upgrade function the system will automatically check for new firmware updates at regular intervals default 10 days In...

Страница 17: ...over the PSTN network You should select Yes for SIP Registration if you want the PBX to consider the adapter as a normal extension In this case you should also enter the IP address of the proxy and th...

Страница 18: ...e a new SIP carrier following these criteria The Proxy IP address should be the socket number of the FXO Port the adapter s IP address followed by semicolon and the FXO Port as defined in the SIP sect...

Страница 19: ...bled the adapter asks the PBX to signal the presence of new voicemail messages Register Expiration The adapter register iself on a regular basis This setting determines the amount of time elapsing bet...

Страница 20: ...ing tones on the phone Alternatively when Before sending 200 OK is selected the adapter sends DTMF signalling before acknowledging the transmission back to the PBX This option enables the adapter to e...

Страница 21: ...3 audio codec iLBC Frame Size Determines the size of the iLBC frames iLBC Payload Type iLBC Payload possible values go from 96 to 127 default 98 Voice Frames per TX Number of frames sent in each audio...

Страница 22: ...either two frequencies MF or only one SF Amongst these signals is the Disconnection Tone Disconnect Examination Mode Here you can configure how the adapter should detect the disconnection tone and it...

Отзывы: