6
regulations); and as smooth as possible inside. It is also advisable to avoid
any drastic changes in duct cross-section (recommended diameter:
125mm).
Decide on the position of the hole for the air outlet: The hole may be in the
wall or the ceiling, according to your requirements, but must be in vertical
line with your hood.
Select the type most suited to your needs and
proceed by mounting the air outlet adapter
(C)
Drill the hole in the wall for the air outlet (133 mm
diameter) referring to drawings here on the right
where the measurements for the various possibilities
are indicated.
Proceed with fixing the hood: Based on your
requirements, you can fit the hood on the wall or on a
wall unit of your kitchen. IMPORTANT: Respect the
distance between the hob and lower part of the hood which must be at least
650mm.
Fixing to the wall
1.
Draw a line on the wall in vertical line with your
hob. Mark the 4 holes to be drilled in the wall,
respecting the distances indicated; Make the 4
holes and fit the 4 screw anchors provided.
Take 2 of the screws provided and insert them
in the topmost screw anchors without, however,
screwing them down completely. Hang the
hood on the 2 screws; Working from inside the
hood, tighten the 2 screws completely.
2.
Now proceed with final fixing by fitting the