7
other 2 screws. Connect a flexible exhaust duct to the hood flange, using
a metal hose clamp. Tube and hose clamps are not provided.
3.
Make the electrical connection.
Fitting under wall unit
1.
Drill 4 holes in the wall unit, respecting the
distance indicated. Push the hood up against
the wall unit and insert the 4 screws operating
from inside the wall unit. Connect a flexible
tube to the hood flange, using a metal hose
clamp. Tube and hose clamps are not
provided.
2.
Make the electrical connection.
Installation is now complete. We recommend you:
CHECK THAT THE DUCTING-RECIRCULATING
LEVER IS IN THE RIGHT POSITION:
The lever
is found on the motor unit and must be positioned
on the symbol E in the case of installation in
ducting version.
·
Also remember that the use of charcoal filter/s is
not necessary with the ducting version; if these are fitted, please remove
them.
Notice:
-Exhaust air must not be discharged into a flue which is used for exhausting
fumes from appliance burning gas or other fuels.
-If the instructions for installation for the gas hob specify a greater distance
than 650mm, this has to be taken into account.