Non-Ducted Recirculation charcoal filter
The non-ducted recirculation charcoal filter should be changed every 6
months.
See “INSTALL FILTERS” section for removal and installation instructions.
INSTALL THE DUCTWORK
(DUCTED HOODS ONLY)
Caution: To reduce the risk of fire, use metal
ductwork is preferred.
1.
Decide where the ductwork will run
between the hood and the outside.
2.
A straight, short duct run will allow the
hood to perform most efficiently.
3.
Long duct runs, elbows, and transitions will reduce the performance of
the hood. Use as few of them as possible. Larger ducting may be
required for best performance with longer duct runs.
4.
The air must not be discharge into a flue that is used for exhausting
fumes from appliances burning gas or other fuels" "Regulations
concerning the discharge of air have to be fulfilled.
5.
Install wall cap. Connect round metal ductwork to cap and work back
towards hood location. Use duct tape to seal the joints between
ductwork sections.