5-4
Vogt
®
VT Service Manual
Electrical Controls
PLC Inputs PLC Outputs
#
Description
#
Description
0
Current Sensing Relay (CSR) for cutter motor
0
Machine Fault Indicator Light
1
“On” Switch & Bin control (in series)
1
Liquid Feed Solenoid (R404A machine only)
2
Harvest Hold (HH) Pressure Switch
2
Compressor
3
Start / Manual Harvest Switch
3
N/A
4
“Clean” Switch
4
Water Pump
5
High Pressure safety
(“off” when tripped)
5
Cutter / "D" valve / Defrost loop valve or
6
Low Pressure safety
(“off” when tripped)
Suction Stop valve
(VT80 & VT100)
7
Oil Safety / Compressor OL
(VT80 & VT100)
FIGURE 5-4
PLC Inputs & Outputs
PLC: FX
1
s
PLC: FXos