![Vogt VT100 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/vogt/vt100/vt100_service-manual_1044460016.webp)
Vogt
®
VT Service Manual
2-9
Installation Instructions
Air Cooled Condenser:
The air cooled condenser will be wired to the condensing unit control panel.
Run two #14 AWG wires and a ground wire from the condensing unit control panel to the Air Cooled
condenser control panel.
208/230V
460V
FIGURE 2-11
VT80 & VT100 Remote Air Cooled Condenser Wiring
Note:
Fan control pressure switch is located in air cooled condenser control panel on VT80 & VT100’s with
remote condensers. On VT40’s and VT60’s, fan control pressure switch is location on condensing unit
(highside).
To Ice Machines
condensing unit
control panel
To Ice
Machines
condensing unit
control panel