Specifications
Series and size
Theoretical capacity*
n
max
= 650 [min
-1
]
Max. differential
pressure*
Theoretical operating torque with
max. differential pressure and
water
(designed for NBR elastomers)
FX116
[l]
[l/min]
[m³/h]
[bar]
[Nm]
60
1.16
750
45
8
183
120
2.32
1500
90
7
317
180
3.48
2250
135
6
429
240
4.64
3000
180
5
481
300
5.80
3800
225
4
492
360
6.96
4500
270
3
462
*
All data refer to theoretical capacity. The actual capacity is lower; it depends on the various operating
conditions.
**
Valid only for short operation times. For continuous operation, please contact our service
department
.
The service time of the rotary lobes is reduced by high temperatures, especially in combination with
high differential pressure.
Free passage
The maximum free passage is
Ø 48 mm
.
ATTENTION
When using the pump for a
highly viscous medium
, the pump speed must be reduced according to the
material's viscosity, to prevent the intake flow from breaking off on the suction side (cavitation protection).
Weights and dimensions
For the machine's weight and dimension specifications, see
"Dimension sheet"