Table 3) Software Resources
4
PHYSICAL ARCHITECTURE
Figure 1) Physical Architecture Overview.
4.1
NETWORK ARCHITECTURE
The networks used for this test were dedicated 1Gb Ethernet. This network was split into three VLANs.
One VLAN was for administrative/public traffic and CIFS access, and the other two were non-routable
VLANs designed for storage and VMotion traffic. All virtual desktops were assigned an IP address using
a DHCP server.
The VMware ESX Server’s networking configuration consisted of ten 1Gb Ethernet Controllers (or NICs).
Two were configured as NIC Teaming ports for NFS traffic and assigned to a pre-defined VMkernel port
used for NFS access with a pre-defined IP address on the non-routable VLAN (i.e. 192.168.1.x). Two
NICs were configured as NIC Teaming ports for VMotion traffic and assigned to a pre-defined, VMotion
enabled VMkernel port with a pre-defined IP address on another non-routable VLAN used solely for
VMotion traffic (i.e. 192.168.0.x). Two NICs were configured as NIC Teaming ports for the Service
Console and assigned to the administrative VLAN. The last four NICs were also configured as NIC
5
Содержание NetApp FAS 2050HA
Страница 1: ......
Страница 16: ...Figure 7 ESX Host NFS Network Configuration Figure 8 ESX Host NFS Load Balancing Network Configuration 15...
Страница 20: ...19 VMware View Composer Deployment Guide VMware View Reference Architecture...