VMware NetApp FAS 2050HA Скачать руководство пользователя страница 11

 
 

Storage required after deduplication 

5GB 

Number of volumes used 

1 (Single parent VM will be used for 
both PODs) 

Size of VM 

10GB 

Volumes for Linked Clones OS Data Disks 

NFS volume storage capacity 

400GB 

Number of volumes used 

4 (two per FAS controller) 

Volume for User Data Disks for Desktops in Persistent  Access Mode (500; 250 per 
FAS controller) 

NFS volume storage capacity 

250GB (2GB per user, 50% 
deduplication savings) 

Number of volumes used 

2 (one per FAS controller) 

Volume for CIFS User Data for Desktops in Non-Persistent  Access Mode (500; 250 
per FAS controller) 

CIFS volume storage capacity 

250GB (2GB per user, 50% 
deduplication savings) 

Number of volumes used per storage controller 

2 (one per FAS controller) 

Table 4: Volume configuration 

4.3 

NETAPP DATA ONTAP CONFIGURATION 

The required NetApp FAS2050HA configurations are as follows: 

NOTE:

 These configurations can be implemented using the Data ONTAP® FilerView or service console 

commands.  The instructions for performing the steps below on the NetApp storage controller are for 
using the FilerView interface.  These configurations can be implemented on any model of NetApp FAS 
storage controllers using the same instructions below.  Also, please be sure to follow the best practices 
for implementing VMware on NetApp storage as recommended in 

TR-3428: NetApp and VMware Virtual 

Infrastructure 3 Storage Best Practices

 

This configuration requires the creation of four volumes per FAS controller.  Two of these volumes will be 
used as NFS based OS datastores for virtual machine files. One of the volumes will be used as a 
datastore for hosting the user data disks for persistent desktop. The other will be a CIFS volume for 
hosting the user data for non-persistent desktops. Please refer to Table 4: Volume Configuration for the 
correct size to use for each volume. 

  10

 
 

Содержание NetApp FAS 2050HA

Страница 1: ......

Страница 2: ...sources 4 4 Physical Architecture 5 4 1 Network Architecture 5 4 2 Storage Architecture 9 4 3 NetApp Data ONTAP Configuration 10 4 4 Intelligent Read Caching 13 4 5 Deduplication Setup 13 4 6 VMware E...

Страница 3: ...ops are in persistent access mode and 500 users are in non persistent access mode This guide can be easily scaled up for larger deployments by simply increasing the number of servers storage controlle...

Страница 4: ...ware View A set of software products that provide services and management infrastructure for centralization of desktop operating environments using virtual machine technology Volume Logical storage co...

Страница 5: ...a ONTAP 7 3 1 NFS License N A VMware ESX Servers 3 5 Update 3 VMware vCenter Server 2 5 Update 3 Windows Servers for vCenter Microsoft Windows Server 2003 Enterprise Edition SP 2 32 Bit Desktops Virtu...

Страница 6: ...tworking configuration consisted of ten 1Gb Ethernet Controllers or NICs Two were configured as NIC Teaming ports for NFS traffic and assigned to a pre defined VMkernel port used for NFS access with a...

Страница 7: ...ic This configuration can either be done in the Data ONTAP GUI or from the Data ONTAP service Console Additionally the multi mode VIF configured for NFS traffic was also assigned an alias IP address t...

Страница 8: ...k interfaces that will make up the NFS VIF 4 For Trunk Mode press the drop down arrow and select Multiple 5 For Load Balancing press the drop down arrow and select IP 6 Click Apply Figure 3 AS2050 NFS...

Страница 9: ...This should be configured as a standard port channel not using any link aggregation protocols such as LACP To configure an ESX server for NFS connectivity follow the below steps Configuration Tab Net...

Страница 10: ...ve Properties Physical Adapters Figure 5 VMware ESX server NIC configuration 4 2 STORAGE ARCHITECTURE The NetApp FAS2050HA was configured with one aggregate and six volumes per controller Each storage...

Страница 11: ...nfigurations are as follows NOTE These configurations can be implemented using the Data ONTAP FilerView or service console commands The instructions for performing the steps below on the NetApp storag...

Страница 12: ...tes as large as possible to benefit from the I O capacity of all the spindles in the aggregate After the creation of the new aggregate the snapshot reserve will need to be turned off by using the belo...

Страница 13: ...een check inside the box Then click Next 5 Determine that the export path is correct for the NFS export 6 At the NFS Export Wizard Read Write Access click on the Add button and enter the IP address of...

Страница 14: ...torage by removing redundant copies of blocks within a volume This process is transparent to the application and can be enabled and disabled on the fly In a VMware View environment using Linked Clones...

Страница 15: ...of NFS Connect to the ESX host s system console using either SSH telnet or serial console and log in to the onsole Type each command below and hit Enter c esxcfg advcfg s 32 NFS MaxVolumes esxcfg adv...

Страница 16: ...Figure 7 ESX Host NFS Network Configuration Figure 8 ESX Host NFS Load Balancing Network Configuration 15...

Страница 17: ...twork cards on the server to achieve high levels of availability 5 VALIDATION RESULTS The storage configuration described in this document was validated by configuring the environment described above...

Страница 18: ...ds Figure 9 Average application execution time in seconds 5 2 STORAGE SYSTEM IO SUMMARY The graphs below show the number of NFS operations for each controller during the duration of the validation The...

Страница 19: ...requirements Most of this information can be found in the NetApp and VMware references below 7 ACKNOWLEDGMENTS The following people contributed to the solution validation and creation of this document...

Страница 20: ...19 VMware View Composer Deployment Guide VMware View Reference Architecture...

Страница 21: ......

Отзывы: