reboot of the storage controller at a future time. In the event the management/CIFS VIF needs to be
created after the initial setup of the FAS2050, please refer to the
Data ONTAP® Software Setup Guide
for
irections in rerunning the setup process for the storage controller.
d
1.
For each NetApp controller, open NetApp FilerView® and click
Network->Add Virtual Interfaces.
2.
Name the new VIF.
3. Select the two network interfaces that will make-up the NFS VIF.
4. For
Trunk Mode
press the drop down arrow and select
Multiple
.
5. For
Load Balancing
press the drop down arrow and select
IP
.
6. Click
Apply
.
Figure 3) AS2050 NFS VIF setup –Create Virtual Interface.
F
1. At
the
Manage Network
Interfaces screen, click on
Modify
for the new VIF that was created in the
previous steps.
2. At
the
Modify Network Interfaces
screen enter a private
IP Address
that will be used for ESX host
NFS connectivity and then enter the
Netmask
and click
Apply
.
3. At
the
Manage Network Interfaces
screen click on
Up
for the new VIF in order to activate it.