9
INSTALLATION
IMPORTANT ________________________
Installation must be performed by properly
trained and qualified persons and comply with
Federal, State and Local Codes for connection
to electrical supplies, water supplies and
pressurized gas systems.
Note:
Vivreau cannot be held responsible for any
damage caused by improper installation.
LOCATION
A completed Pre-installation Checklist
must
be available prior to installation. The Vivreau
Dispensing System must be installed indoors
where the ambient air temperature will not exceed
90°F.
The Vivreau Dispensing System should not be
exposed to spills, spray, steam or high humidity.
A suitable location should be chosen within 40” of
the electrical and water supply connections.
Vivreau Model V3-201
is designed to be fitted
flush on the left, right and rear.
The unit incorporates a Rear Spacer. The area
around the Rear Spacer must be kept clear, as
warm air must vent from the top-rear of the unit.
Vivreau Model V3-202
is designed to be installed in
an under-counter space with adequate ventilation
for component cooling.
Do not
obstruct air vents.
Install the system on a firm, level floor.
CONNECTIONS
WARNING
This unit must be electrically
grounded.
ELECTRICAL
Power Supply:
120V 60Hz
Power Supply Connection Type:
NEMA 5-20 plug
Grounded, with proper circuit protection.
CO
2
A Cylinder of food-grade CO
2
gas is required. Only
use non-syphon type Cylinders.
IMPORTANT ________________________
Before connecting, with the Cylinder Outlet
turned away, open Valve for short blast and
close immediately. This will clear any debris
from the outlet.
CO
2
Cylinder
must
be installed vertically and
secured with a Chain, Strap or Bracket.
CAUTION
CO
2
Cylinders should always be
secured in the vertical position with the Outlet
Valves positioned at the top. This will help
prevent injury caused by the entry of liquid
Carbon Dioxide into the Pressure Regulator.
CO
2
Cylinder Installation
Содержание V3-202