7
Installation
INTRODUCTION
The Vivreau V3-201 and V3-202 Dispensing
Systems are free-standing and under-counter
Water Dispensing Systems. Chilled water is
available from Dispensers that provide Still and
Carbonated Water from individual faucets.
Vivreau V3-201 and V3-202 Dispensing Systems
PRE-INSTALLATION
Below are the services required to be in place
prior to the installation of the Vivreau V3-201 or V3-
202 Dispensing System. If you have any questions
regarding these or other services, please contact
Vivreau Service
Toll-Free at 877-999-1044.
WATER SUPPLY
One (1) potable 1/2” cold water supply terminating in
a 1/2” NPT Ball Valve, 1/2” female pipe thread.
IMPORTANT ________________________
Ball Valve must be accessible for service and
installation.
Minimum Water Pressure:
50 PSI
Minimum Water Flow:
80 gallons per hour
IMPORTANT ________________________
The Vivreau V3-201 and V3-202 Dispensing
System incorporates back-flow prevention. Any
additional back-flow devices required by Federal,
State or Local Code must also be supplied by the
customer prior to installation. There must not be
any other Filters/Pre-Filters inline before the unit.
ELECTRICAL OUTLET
Model V3-201 and V3-202
(1) 20 Amp Electrical Circuit (NEMA 5-20R) 120V,
60 Hz (11 Amps)
CO
2
CO
2
Cylinder (Customer supplied) - Size should
be selected based on available space. A 20 lb.
cylinder will fit inside unit.
NOTE:
If connecting to a bulk or existing CO
2
system, a CO
2
line terminating at a 1/4” Barbed
Shutoff Valve must be available within 40” of the
unit with 100 PSI minimum pressure.
DRIP TRAY AND DISPENSING HEAD
CUTOUTS
(Model V3-202 Only)
Cut out the holes for the Drip Tray and Dispensing
Head per the supplied template.
NOTE:
The Dispensing Head must be mounted
on the work surface directly above the Chiller/
Carbonator.
1
5
/
8
"
2
7
/
8
"
3
7
/
8
"
5
1
/
8
"
12
1
/
8
"
Dispensing Head Dimensions
VENTILATION
If the system is to be installed in an enclosed
space or in a cabinet, adequate ventilation must
be provided.
CAUTION
Failure to provide adequate
ventilation will cause system failure.
This unit is to be installed indoors only.