VIVOTEK
140 - User's Manual
patrolseq
string[64]
1/4
(For external device)
The indexes of patrol points, separated by “,”
patroldwelling
string[128]
1/4
(For external device)
The dwelling time of each patrol point, separated by “,”
preset_i<0~(npre
set-1)>_name
string[40]
1/4
Name of the preset location.
preset_i<0~(npre
set-1)>_dwelling
0~999
1/4
The dwelling time of each preset location.
uart
0 ~ (m-1), m
is UART count
1/4
Select corresponding uart
(capability.nuart>0).
cameraid
0~255
1/4
Camera ID controlling external PTZ camera.
isptz
0 ~ 2
1/4
0: disable PTZ commands.
1: enable PTZ commands with PTZ driver.
2: enable PTZ commands with UART tunnel.
disablemdonptz
<boolean>
1/4
Disable motion detection on PTZ operation.
Group:
uart
(capability.uart>0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~1
9,127>_name
string[40]
1/4
Name of the PTZ driver.
ptzdrivers_i<0~1
9,127>_location
string[128]
1/4
Full path of the PTZ driver.
enablehttptunnel
<boolean>
4/4
Enable HTTP tunnel channel to control UART.
Group:
uart_i<0~(n-1)>
n is uart port count
(capability.nuart>0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600
,1200,2400,
3600,4800,7
200,9600,19
200,38400,5
7600,115200
4/4
Set baud rate of COM port.
databit
5,6,7,8
4/4
Data bits in a character frame.
paritybit nne,odd,eve
n
4/4
For error checking.
stopbit
1,2 4/4 1,
2-1.5,data bit is 5