VIVOTEK
66 - User's Manual
The following message is displayed when attempting to upload an incorrect file format.
Export language file
: Click to export language strings. VIVOTEK provides nine languages: English,
Deutsch, Español, Français, Italiano,
日本語,
Português,
簡体中文
, and
繁體中文
.
Update custom language file: Click
Browse…
and specify your own custom language file to upload.
Export configuration file: Click to export all parameters for the device and user-defined scripts.
Update configuration file: Click
Browse…
to update a configuration file. Please note that the model and
firmware version of the device should be the same as the configuration file. If you have set up a fixed IP
or other special settings for your device, it is not suggested to update a configuration file.
Export server staus report
: Click to export the current server status report, such as time, logs,
parameters, process status, memory status, file system status, network status, kernel message ... and so
on.
Tips:
If a firmware upgrade is accidentally disrupted, say, by a power outage, you still have a last resort method to
restore normal operation. See the following for how to bring the camera back to work:
Applicable scenario:
(1) Power disconnected during firmware upgrade.
(2) Unknown reason causing abnormal LED status, and a Restore cannot recover normal working
condition.
You can use the following methods to activate the camera with its backup firmware:
(1) Press and hold down the reset button for at least one minute.
(2) Power on the camera until the Red LED blinks rapidly.
(3) After boot up, the firmware should return to the previous version before the camera hanged. (The
procedure should take 5 to 10 minutes, longer than the normal boot-up process). When tthis
process is completed, the LED status should return to normal.