VIVOTEK
User's Manual - 17
14.
Prepare two power lines as the 24V inputs for the camera. Connect the input lines from
the enclosure's terminal to that on the camera. Also connect the DO- (black) and the
DO+ (red) lines from the IR unit to the camera's terminal connector. You only need to
connect one pair of LED ON/OFF mode DI wires to the camera.
DO+
DO-
DI1+
DI2+
DI3+
DI-
RS485-
RS485+
AC/DC pwr
AC/DC pwr
The LED ON/OFF mode DI connection enables the synchronization of IR light and the
automated day/night switching mechanism on the camera.
Listed below is the color scheme for wires coming fom the IR light units.
Description
Color
Gauge
IR status DO-
Orange
(26AWG)
IR status DO+
Brown
(26AWG)
LED ON/OFF mode DO-
Black
(26AWG)
LED ON/OFF mode DO+
Red
(26AWG)
Input(V-): 24V AC/DC or 12V DC
Orange
(20AWG)
Input(V+): 24V AC/DC or 12V DC
Brown
(20AWG)
Output(V-): Volts same as input
Black
(20AWG)
Output(V+): Volts same as input
Red
(20AWG)