DK8500Z DLP Projector Remote Communication Manual
2
RM85001117EN00
The Serial Interface RS-232 Command
This projector supports to control by RS-232 command, there exist two types of RS-232 serial commands:
Operation command: Available menu options are INPUT, PICTURE, ALIGNMENT, CONTROL and SERVICE.
Simulated IR remote controller commands: Controls projector via RS-232 command, the commands simulate IR
remote controller and its control keys.
Communication parameter
You can use the serial control command to input commands for projector control or retrieve its operational data
through Windows client terminal software, e.g. Hyper Terminal, with ASCII characters. You need to set up the following
communication parameters in advance:
Item
Parameter:
Bit per Second
9600 bps
Data Bit
8-bit
Parity None
Stop Bit
1
Flow Control
None
Port 7000
Note:
The terminal software does not return every command input character
The transmission performance varies with the length of RS-232 cable
Operation commands
Operation command syntax
An operation command is prefixed by character "op", followed by control commands and settings separated by
space blank [SP], and ended by carriage return pair "CR" and "ASCII hex 0D".Syntax of serial control
commands:
op[SP]<operation command>[SP]<Setting Value>[CR]
op :
A constant indicating this is an operation command.
[SP] :
Indicate one blank space.
[CR] :
Indicate the command ending carriage return pair "CR" and "ASCII hex 0D".
Setting value :
Settings of operation command
Types of setup strings
Characters of settings
Description
Query current setup
?
Question mark "?" indicates querying current setup
Setup
= <settings>
Syntax: Symbol "=" suffixed with setup values
Increase setup order of
adjustment items
+
Some settings are changed in steps. Symbol "+"
indicates changing one step up
Decrease setup order of
adjustment items
-
Some settings are changed in steps. Symbol "-"
indicates changing one step down
Execute operation command
None
Certain operation commands execute after input
without further setting or regulators.
Examples:
Control items
Input command
Projector return message
Query current brightness
op bright ? [CR]
OP BRIGHT = 101
Set up brightness
op bright = 127 [CR]
OP BRIGHT = 127
Set up input signal source to
HDMI
op input.sel = 0 [CR]
OP INPUT.SEL = 0
Reset projection lens to
center position
lens.center
Note:
When sending the multiple commands, make sure the return message of the last command is received
before sending out the next one.
Содержание DK8500Z
Страница 1: ...DK8500Z Remote Communicaton Manual ...