Mount Thermostat

Align the 4 tabs on the subbase with 

corresponding slots on the back of the 

thermostat, then push gently until the 

thermostat snaps in place. 

7

MOUNT THERMOSTAT & BATTERY INSTALLATION

Battery Installation

To release battery cover

press finger bevel on the 

left side and lift the cover 

to access batteries. 

Simple operating instructions are 

found on the back of the battery door.

Battery installation is recommended even if thermostat is hardwired (C terminal connected).  When 

thermostat is hardwired and batteries are installed, the thermostat will activate a compressor delay of 5 

minutes when the thermostat detects a power outage from the hardwired power supply.

Important: 

 

 

High quality alkaline batteries are recommended.  

Rechargeable batteries or low quality batteries do not 

guarantee a 1-year life span.

Refer to your Operating Manual

for programming and operation 

instructions A copy can be

downloaded at www.pro1iaq.com

Replace AA Batteries when low battery indicator shows in display.

Select Heat, Off, or Cool as 

needed. Select Fan On for 

continuous operation or 

Auto to cycle fan with system.

Note:

 

To insure a solid fit between the 

thermostat and the subbase:

     Mount subbase to a flat wall

     Use screws provided

     Drywall anchors should be flush with the wall

     Wires should be pushed into the wall

1.

2.

3.

4.

5:23

PM

F

Tue

Menu

Auto

Off

Содержание S-855C Series

Страница 1: ...ttery Power Hardwire Common Wire Hardwire Common Wire with Battery Backup Power Type 1 Specifications Rev 1413 A trained experienced technician must install this product Carefully read these instructi...

Страница 2: ...there are dead spots or drafts in corners or behind doors Where there might be concealed chimneys or pipes Pick an installation location that is easy for the user to access The temperature of the loca...

Страница 3: ...the bottom edge of the badge Gently turn the screwdriver counter clockwise The badge is held on by a magnet The badge should pry off easily Do not use force Magnet in door Use the bevel on lower ridge...

Страница 4: ...disconnect the power before beginning to install this product can cause electric shock or equipment damage Caution Mercury Notice Vertical Mount Horizontal Mount Vertical Mount Horizontal Mount 4 SUBB...

Страница 5: ...Typical 2H 2C system 1 transformer Typical 2H 2C system 2 transformer COMPRESSOR RELAY FAN RELAY HEAT RELAY 4 2 1 C R L2 L1 HOT C R L2 L1 HOT REMOVE JUMPER Typical heat only system HEAT RELAY 4 2 1 C...

Страница 6: ...l System 2 Heat 2 Cool Heat Pump System 3 Heat 2 Cool Heat Pump System RC RH C B O G W E Y Y2 W2 Transformer Power cooling Transformer Power heating Transformer common Energized in heating Energized i...

Страница 7: ...ompressor delay of 5 minutes when the thermostat detects a power outage from the hardwired power supply Important High quality alkaline batteries are recommended Rechargeable batteries or low quality...

Страница 8: ...r example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approximately 0 5 F above the setpoint The cooling swing setting is ad...

Страница 9: ...lock setting 12 Hour Clock Morning Recovery This feature will start heating early to bring the building temperature to its programmed setpoint by the beginning of the time period WAKE OCCUPIED Use the...

Страница 10: ...ption will turn the heat pump off 45 seconds after the auxiliary heat relay turns on For 2 heat applications the first stage will turn off 45 seconds after the auxiliary stage turns on For 3 heat appl...

Страница 11: ...to select OFF 1YEAR 2YEAR IAQ Cell Reminder Will remind the user to change the PHI Cell after 25 000 hrs Use the or key to select OFF 250 Stands for 25000 hours IAQ Mode Cycle This feature will confi...

Страница 12: ...rent hour When using 12 hour time make sure the correct a m or p m choice is selected Press NEXT Minutes are now flashing Use the or key to select current minutes Press DONE when completed 1 2 3 4 5 6...

Страница 13: ...n OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Occupied Unocc...

Страница 14: ...me period and for Saturday SLEEP UNOCC2 time period Repeat steps 4 through 7 for Sunday WAKE OCC1 time period for Saturday LEAVE UNOCC1 time period for Sunday RETURN OCC2 time period and for Saturday...

Страница 15: ...PROGRAMMING 15 If you want to use IAQ mode during this time period select IAQ with the fan key Sunday time If you want to use IAQ mode during this time period select IAQ with the fan key...

Страница 16: ...riod begins Your program setpoint will then replace your temporary setpoint Permanent hold If you press the HOLD key at the bottom of your screen you will see HOLD appear below the setpoint temperatur...