FEATURES & SPECIFICATIONS
16
The display range of temperature
The control range of temperature
Load rating
Display accuracy
Swing (cycle rate or differential)
Power source
Operating ambient
Operating humidity
Dimensions of thermostat
41ºF to 95ºF (5ºC to 35ºC)
44ºF to 90ºF (7ºC to 32ºC)
1 amp per terminal, 1.5 amp maximum all terminals combined
± 1ºF
Heating is adjustable from 0.2ºF to 2.0ºF
Cooling is adjustable from 0.2ºF to 2.0ºF
18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire (common wire)
Battery power from 2 AA Alkaline batteries
32ºF to +105ºF (0º to +41ºC)
90% non-condensing maximum
4.9 ”W
x 4.5
”H x 1.0”D
Specifications
Temporary and Permanent Hold Feature
Temporary hold:
The thermostat will display
HOLD
and
RUN SCHED
on the bottom
of your screen when you press the or
key. If you do nothing, the temperature will
remain at this setpoint temporarily until the
next program period begins. Your program
setpoint will then replace your temporary
setpoint.
Permanent hold:
If you press the
HOLD
key at
the bottom of your screen, you will see
HOLD
appear below the setpoint temperature in the
display. The thermostat will now permanently
stay at this setpoint and can be adjusted
using the or keys.
To return to program:
Press the
RUN
SCHED
key at the bottom of your screen
to exit either temporary or permanent hold.
If your installing contractor has configured
the thermostat to remind you when the air
filter needs changed, you will see
FILT
display when your air filter needs changed.
will be shown in the display after your
system has run long enough to require an air
filter change.
Resetting the filter change reminder: When
reminder is displayed, you should
change your air filter and reset the reminder
by holding down the 3rd button from the
left side of the thermostat for 3 seconds.
This thermostat also has other maintenance
reminders (Humidity Pad, UV lamp, and IAQ
Cell), that are reset with the same procedure.
FILT
Filter Change and other Reminders