TECHNICIAN SETUP MENU

11

OFF

1

OFF

Adjustment Options

LCD Will Show

Tech Setup Steps (Continued from the previous page)

OFF

OFF

Factory Default Settings

Cooling Fan

Delay

The cooling fan 

delay setting will 

delay the fan from 

coming on in cool

mode and keep

running after the

compressor shuts 

off for a short time 

to save energy in 

some systems. 

You can select the 

Cooling Fan Delay

from OFF, 15, 30, 60 

or 90 Seconds. 

COOL FAN DL

Satisfy Setpoint

This feature allows 

the thermostat to 

keep multiple stages 

of heat or cool 

energized until 

setpoint is satisfied. 

Use the           or    

key to turn on or 

off. 

Staging Delay

This feature allows a 

delay to occur when 

a second and third 

stage is needed. This 

allows the previous 

stage extra time to 

satisfy setpoint. 

Use the            or    

key to select YES, 5, 

10, 15, 30, 45, 60, or 

90 minutes. 

Humidity Pad 

Reminder

This will remind the 

user to change the 

humidity pad. 

Use the            or     

key to select OFF, 

600, 1000, 1500, 

2000.  These 

represent hours of 

heat operation. 

UV Lamp 

Reminder

Will remind the user 

to change the UV 

light bulb.

Use the            or      

key to select OFF, 

1YEAR, 2YEAR. 

IAQ Cell 

Reminder

Will remind the user 

to change the PHI 

Cell after 25,000 hrs.

Use the            or      

key to select OFF, 

250. (Stands for 

25000 hours) 

IAQ Mode Cycle

This feature will 

configure the fan to 

run a selected 

number of cycles

“per hour”.

Note: This mode can 

be enabled or 

disabled at anytime 

during normal 

operation, by 

selecting IAQ mode 

with the fan key.

Select OFF, 1,2,3 or 4

with the           or   

keys.

This sets the number 

of cycles per hour 

that the IAQ fan 

mode will operate. 

IAQ MODE CYCLE

OFF

IAQ MODE M INUT

IAQ Mode Minutes

This allows you to 

select the minimum 

number of minutes 

that the fan will run 

“Per Cycle “.  The 

thermostat will keep 

track of fan run time 

from normal Heat 

and Cool operation. 

If additional fan 

runtime is needed, 

the thermostat will 

run the fan to satisfy 

the IAQ mode 

minutes.

Select 1, 5, 10 ,15 

,20 ,30  or 45 

minutes.

When IAQ fan mode 

is enabled, it will 

ensure the fan runs 

at least the selected 

number of minutes 

per IAQ mode cycle.

1

OFF

OFF

This Programmable/Selectable mode will operate the fan 1-4 cycles per hour, 1-45 minutes per 

cycle.  Once programmed in Tech Setup, to enable this mode select ‘IAQ’ with the Fan Key.  Or you

can disable the mode by selecting ‘ON’ or ‘AUTO’ with the Fan Key.

A Note about IAQ Mode:

Содержание S-855C Series

Страница 1: ...ttery Power Hardwire Common Wire Hardwire Common Wire with Battery Backup Power Type 1 Specifications Rev 1413 A trained experienced technician must install this product Carefully read these instructi...

Страница 2: ...there are dead spots or drafts in corners or behind doors Where there might be concealed chimneys or pipes Pick an installation location that is easy for the user to access The temperature of the loca...

Страница 3: ...the bottom edge of the badge Gently turn the screwdriver counter clockwise The badge is held on by a magnet The badge should pry off easily Do not use force Magnet in door Use the bevel on lower ridge...

Страница 4: ...disconnect the power before beginning to install this product can cause electric shock or equipment damage Caution Mercury Notice Vertical Mount Horizontal Mount Vertical Mount Horizontal Mount 4 SUBB...

Страница 5: ...Typical 2H 2C system 1 transformer Typical 2H 2C system 2 transformer COMPRESSOR RELAY FAN RELAY HEAT RELAY 4 2 1 C R L2 L1 HOT C R L2 L1 HOT REMOVE JUMPER Typical heat only system HEAT RELAY 4 2 1 C...

Страница 6: ...l System 2 Heat 2 Cool Heat Pump System 3 Heat 2 Cool Heat Pump System RC RH C B O G W E Y Y2 W2 Transformer Power cooling Transformer Power heating Transformer common Energized in heating Energized i...

Страница 7: ...ompressor delay of 5 minutes when the thermostat detects a power outage from the hardwired power supply Important High quality alkaline batteries are recommended Rechargeable batteries or low quality...

Страница 8: ...r example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approximately 0 5 F above the setpoint The cooling swing setting is ad...

Страница 9: ...lock setting 12 Hour Clock Morning Recovery This feature will start heating early to bring the building temperature to its programmed setpoint by the beginning of the time period WAKE OCCUPIED Use the...

Страница 10: ...ption will turn the heat pump off 45 seconds after the auxiliary heat relay turns on For 2 heat applications the first stage will turn off 45 seconds after the auxiliary stage turns on For 3 heat appl...

Страница 11: ...to select OFF 1YEAR 2YEAR IAQ Cell Reminder Will remind the user to change the PHI Cell after 25 000 hrs Use the or key to select OFF 250 Stands for 25000 hours IAQ Mode Cycle This feature will confi...

Страница 12: ...rent hour When using 12 hour time make sure the correct a m or p m choice is selected Press NEXT Minutes are now flashing Use the or key to select current minutes Press DONE when completed 1 2 3 4 5 6...

Страница 13: ...n OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Occupied Unocc...

Страница 14: ...me period and for Saturday SLEEP UNOCC2 time period Repeat steps 4 through 7 for Sunday WAKE OCC1 time period for Saturday LEAVE UNOCC1 time period for Sunday RETURN OCC2 time period and for Saturday...

Страница 15: ...PROGRAMMING 15 If you want to use IAQ mode during this time period select IAQ with the fan key Sunday time If you want to use IAQ mode during this time period select IAQ with the fan key...

Страница 16: ...riod begins Your program setpoint will then replace your temporary setpoint Permanent hold If you press the HOLD key at the bottom of your screen you will see HOLD appear below the setpoint temperatur...

Отзывы: