TECHNICIAN SETUP MENU
11
OFF
1
OFF
Adjustment Options
LCD Will Show
Tech Setup Steps (Continued from the previous page)
OFF
OFF
Factory Default Settings
Cooling Fan
Delay
The cooling fan
delay setting will
delay the fan from
coming on in cool
mode and keep
running after the
compressor shuts
off for a short time
to save energy in
some systems.
You can select the
Cooling Fan Delay
from OFF, 15, 30, 60
or 90 Seconds.
COOL FAN DL
Satisfy Setpoint
This feature allows
the thermostat to
keep multiple stages
of heat or cool
energized until
setpoint is satisfied.
Use the or
key to turn on or
off.
Staging Delay
This feature allows a
delay to occur when
a second and third
stage is needed. This
allows the previous
stage extra time to
satisfy setpoint.
Use the or
key to select YES, 5,
10, 15, 30, 45, 60, or
90 minutes.
Humidity Pad
Reminder
This will remind the
user to change the
humidity pad.
Use the or
key to select OFF,
600, 1000, 1500,
2000. These
represent hours of
heat operation.
UV Lamp
Reminder
Will remind the user
to change the UV
light bulb.
Use the or
key to select OFF,
1YEAR, 2YEAR.
IAQ Cell
Reminder
Will remind the user
to change the PHI
Cell after 25,000 hrs.
Use the or
key to select OFF,
250. (Stands for
25000 hours)
IAQ Mode Cycle
This feature will
configure the fan to
run a selected
number of cycles
“per hour”.
Note: This mode can
be enabled or
disabled at anytime
during normal
operation, by
selecting IAQ mode
with the fan key.
Select OFF, 1,2,3 or 4
with the or
keys.
This sets the number
of cycles per hour
that the IAQ fan
mode will operate.
IAQ MODE CYCLE
OFF
IAQ MODE M INUT
IAQ Mode Minutes
This allows you to
select the minimum
number of minutes
that the fan will run
“Per Cycle “. The
thermostat will keep
track of fan run time
from normal Heat
and Cool operation.
If additional fan
runtime is needed,
the thermostat will
run the fan to satisfy
the IAQ mode
minutes.
Select 1, 5, 10 ,15
,20 ,30 or 45
minutes.
When IAQ fan mode
is enabled, it will
ensure the fan runs
at least the selected
number of minutes
per IAQ mode cycle.
1
OFF
OFF
This Programmable/Selectable mode will operate the fan 1-4 cycles per hour, 1-45 minutes per
cycle. Once programmed in Tech Setup, to enable this mode select ‘IAQ’ with the Fan Key. Or you
can disable the mode by selecting ‘ON’ or ‘AUTO’ with the Fan Key.
A Note about IAQ Mode: